Belden 3108A PVC or 3108DB CPE Direct Burial

Use 3108A for the PVC jacket at 0.374 in and 60°C. Use 3108DB for the CPE direct-burial jacket at 0.411 in and 90°C. Both list 120 Ohm and 4.2 A at 30°C.

Rust Belt Industrials · October 27, 2026 · Updated October 28, 2026 · 5 min read

On this page

Use Belden 3108A when the 3-pair 22 AWG cable is the industrial PVC jacket. As of October 27, 2026, that sheet lists a nominal diameter of 0.374 in (9.50 mm), UL temperature 60°C, operating temperature -20°C to +60°C, and 4.2 A per conductor at 30°C. Use Belden 3108DB when the cable is the CPE direct-burial jacket. As of the same day, that sheet lists a nominal diameter of 0.411 in (10.4 mm), UL temperature 90°C, operating temperature -40°C to +90°C, and the same 4.2 A per conductor at 30°C. Both sheets list 120 Ohm and conductor DCR of 18.2 Ohm/1000ft. The April 2022 line card lists 3108A as industrial PVC, CM/PLTC, and 3108DB as CPE, CM/PLTC, UL Direct Burial. Four pairs of the PVC construction are 3109A, on the 3108A and 3109A page.

PVC and CPE are separate rows at the same pair count

As of October 27, 2026, the line card lists 3108A at 3 pair, 22 AWG, industrial PVC, CM/PLTC, industrial and other harsh environment. The next burial block lists 3108DB at 3 pair, 22 AWG, CPE, CM/PLTC, UL Direct Burial, and the same harsh-environment column. 3108A's product note says a CPE jacketed version is ordered as YR45287. That page was not opened. 3108DB is the direct-burial CPE sheet opened for this comparison. YR45287 stays the number in the 3108A note.

22 AWG pairs, with the jacket and water block from the sheet

As of October 27, 2026, both sheets list three pairs of 22 AWG (7x30) tinned copper, foam polyethylene insulation of 0.023 in (0.58 mm), a nominal insulation diameter of 0.075 in (1.9 mm), notes HDPE, and the blue, orange, and green stripe pairs. Both shields are a 100% bi-laminate tape, a 22 AWG (7x30) tinned-copper drain, and a 65% tinned-copper braid. 3108DB adds a waterblock tape. 3108A does not print a waterblocking line. 3108A's jacket is PVC, 0.053 in (1.3 mm), nominal diameter 0.374 in (9.50 mm). 3108DB's jacket is CPE, chlorinated polyethylene, 0.055 in (1.4 mm), nominal diameter 0.411 in (10.4 mm). The 3108DB product description names Datalene insulation and prints DIR BUR in the title block. The construction cell still says foam polyethylene, notes HDPE.

3108A and 3108DB rows from the sheets opened October 27, 2026.
Item3108A3108DB
Line-card jacketIndustrial PVCCPE, UL Direct Burial
Nominal jacket OD0.374 in (9.50 mm)0.411 in (10.4 mm)
UL temperature60°C90°C
Operating range-20°C to +60°C-40°C to +90°C
Current4.2 A per conductor at 30°C4.2 A per conductor at 30°C
Conductor DCR18.2 Ohm/1000ft18.2 Ohm/1000ft
Water blockNot printedWaterblock tape
Oil noteOil Res IIOil Res I and II

120 Ohm and 4.2 A, with the oil note from the sheet

As of October 27, 2026, both sheets list conductor DCR of 18.2 Ohm/1000ft, capacitance of 11 pF/ft (36 pF/m) conductor to conductor and 20.9 pF/ft (68.6 pF/m) conductor to other, impedance of 120 Ohm, inductance of 0.225 µH/ft (0.738 µH/m), velocity of 78%, insertion loss of 0.5 dB/100ft at 1 MHz, and 4.2 A per conductor at 30°C. Outer-shield DCR is 3.576 Ohm/1000ft (11.73 Ohm/km) on both. Voltage is 300 V (CM, PLTC) on both. The oil note on 3108A says the cable passes Oil Res II per UL 1277, Table 10.17. The oil note on 3108DB says it passes Oil Res I and II per the same table. Copy the oil line from the sheet you named.

Direct burial is the title and the applications line

3108DB's title includes Sun Res and Dir Bur, as of October 27, 2026. The applications cell includes direct burial and outdoor uses such as solar and lighting. The suitability cell lists indoor, outdoor, sunlight resistance, and oil resistance. It does not repeat the words direct burial. The line card is the page that prints UL Direct Burial on the 3108DB row. 3108A's suitability cell is indoor, outdoor, sunlight resistance, and oil resistance, and its title does not say Dir Bur. Installation temperature is printed on 3108DB, -20°C to +90°C. 3108A does not print an installation-temperature cell.

As of October 27, 2026, 3108A lists minimum bend radius 4.488 in (114.0 mm), maximum pull tension 90 lbs (41 kg), and weight 63 lbs/1000ft. 3108DB lists minimum bend radius 4.932 in (125.3 mm), the same 90 lbs (41 kg) pull tension, and weight 77 lbs/1000ft. Neither weight cell prints a kilogram. Flammability on both is UL 1685 UL Loading and IEC 60332-1-2. NEC compliance is Article 725, Article 800, CM, PLTC. CEC compliance is CM. 3108A prints CPR Euroclass Eca and a UKCA Mark line. 3108DB does not print a CPR line or a UK regulation line. 3108A page revision is 0.552, dated 02-20-2026, with black reels at 1,000 ft, 2,000 ft, and 5,000 ft. 3108DB page revision is 0.388, dated 10-07-2026. That sheet does not print a variant table.

What to copy onto the cable line

  • Part: 3108A or 3108DB, from the sheet opened October 27, 2026.
  • Jacket: PVC at 0.374 in (9.50 mm), or CPE at 0.411 in (10.4 mm).
  • Burial: Dir Bur on the 3108DB title and applications line, and UL Direct Burial on the April 2022 line card.
  • Temperature: UL 60°C and -20°C to +60°C, or UL 90°C and -40°C to +90°C, plus the installation cell on 3108DB.
  • Current and impedance: 4.2 A per conductor at 30°C, and 120 Ohm, on the part you named.
  • Oil: Oil Res II, or Oil Res I and II.

3108A or 3108DB note

Name PVC or CPE, and copy the temperature line from that sheet.

This prepares a request. It does not send one.

Questions these sheets answer

Does the burial jacket change the 4.2 A cell?

Both sheets print 4.2 A per conductor at 30°C and 120 Ohm, as of October 27, 2026. Jacket, diameter, UL temperature, and the oil line are the cells that differ.

Is YR45287 the same part as 3108DB?

3108A's note names YR45287 for a CPE jacket, as of October 27, 2026. That page was not opened. 3108DB is the direct-burial sheet, with Dir Bur in the title and a waterblock tape. The request names the number on the sheet it is copying.

Which cell says direct burial?

The 3108DB title and applications cell say direct burial, as of October 27, 2026. The suitability cell lists sunlight and oil and does not repeat those two words. The line card prints UL Direct Burial. Copy the title and the line-card rating together when the drawing asks for the burial listing.

Sources

Jacket, diameter, temperature, current, oil, and the waterblock line are from the Belden 3108A and 3108DB technical data sheets. The industrial PVC row and the CPE UL Direct Burial row are from the Belden RS-485 line card dated April 2022. All three were opened October 27, 2026. YR45287 was named and not opened. The 4-pair PVC and CPE sheets are 3109A and 3109DB, on the 3109A and 3109DB page.