Industrial networking
Belden 7919A Foil or 7923A Bonded Pairs for Mining Cat 5e
Use 7919A for the foil-shielded mining cable at 0.265 in and P-07-KA060004-MSHA. Use 7923A for the bonded-pair mining cable at 0.230 in and P-07-KA060003-MSHA. Both list 24 AWG and MSHA CMR.
On this page
Use Belden 7919A when the mining Cat 5e cable is the foil-shielded sheet. As of November 5, 2026, that sheet lists a PVC jacket of 0.265 in (6.73 mm), an overall Beldfoil shield, UL temperature 60°C, and other-standard compliance P-07-KA060004-MSHA. Use Belden 7923A when the mining Cat 5e cable is the bonded-pair sheet. As of the same day, that sheet lists a PVC jacket of 0.230 in (5.84 mm), UL temperature 75°C, bonded pairs, and other-standard compliance P-07-KA060003-MSHA. The 7923A description does not name a shield, and the construction block that was read has no outer-shield section. Both titles say DataTuff Cat 5e, 24 AWG solid bare copper, and MSHA CMR. Both list 300 V (CMR) and 300 V (CMX-Outdoor). The shielded industrial cable at 0.33 in, without an MSHA cell, is on the 7921A and 7922A page.
Four 24 AWG pairs, foil on 7919A, bonded pairs on 7923A
As of November 5, 2026, both sheets list four pairs of 24 AWG solid bare copper and polyolefin insulation. Pair colors are white/blue stripe and blue, white/orange stripe and orange, white/green stripe and green, and white/brown stripe and brown. 7919A's shield is a polyester plus bi-laminate tape at 100% coverage, with a 24 AWG (7x32) tinned-copper drain. The description names an overall Beldfoil shield. The jacket is PVC, nominal diameter 0.265 in (6.73 mm). The sheet does not print a bonded-pair line. 7923A prints bonded pair: yes. The construction block moves from that line to the PVC jacket, nominal diameter 0.230 in (5.84 mm), with a ripcord. It does not print an outer-shield section or a drain. 7923A's description is industrial Ethernet Cat 5e, four bonded-pair 24 AWG solid bare copper, polyolefin insulation, PVC jacket, MSHA CMR. A patent note points to belden.com/patents and does not print a patent number. 7919A does not print that patent note. Suitable applications on both name mining, harsh environment, IIoT, factory or process automation, IP cameras and devices, and data communication. Neither sheet prints the other part number.
| Item | 7919A | 7923A |
|---|---|---|
| Jacket | PVC, 0.265 in | PVC, 0.230 in |
| Shield block | Beldfoil, 100% tape | No outer-shield section |
| Pairs | 4, not marked bonded | 4 bonded pairs |
| Conductor DCR | 28.6 Ohm/1000ft | 28.6 Ohm/1000ft |
| Capacitance unbalance | 330 pF/ft | 66 pF/ft |
| UL temperature | 60°C | 75°C |
| MSHA string | P-07-KA060004-MSHA | P-07-KA060003-MSHA |
| NEC line | CMR, CMX-Outdoor | CMR, CMX-Outdoor, CMG |
28.6 Ohm/1000ft matches, and 330 pF/ft does not
As of November 5, 2026, both sheets list maximum conductor DCR of 93.8 Ohm/km (28.6 Ohm/1000ft). Maximum capacitance unbalance is 330 pF/ft on 7919A and 66 pF/ft on 7923A. Maximum delay is 538 ns/100m on 7919A and 510 ns/100m on 7923A. Maximum delay skew is 45 ns/100m on 7919A and 25 ns/100m on 7923A. Nominal velocity is 70% on both. Voltage is 300 V (CMR) and 300 V (CMX-Outdoor) on both. 7919A's fitted and unfitted impedance cells at 1 MHz through 100 MHz print 100 plus or minus 15 Ohm. 7923A's unfitted impedance cell at 1 MHz prints 100 plus or minus 12 Ohm, and the fitted cell at 1 MHz prints 105 plus or minus 10 Ohm. The later frequency rows change those windows. This page does not copy the full NEXT table. Insertion loss at 100 MHz is 22.0 dB/100m on 7919A and 26.0 dB/100m on 7923A.
UL 60°C on 7919A, UL 75°C and CMG on 7923A
As of November 5, 2026, 7919A lists UL temperature 60°C, operating temperature -40°C to +75°C, and installation temperature -25°C to +75°C. The temperature block does not print a storage column. Stationary bend radius is 1 in (25 mm). Pull tension is 25 lbs (11 kg). Bulk weight is 30 lbs/1000ft. Suitability includes indoor, outdoor, sunlight resistance, oil resistance, and aerial. NEC / UL compliance is Article 800, CMR, CMX-Outdoor. CEC compliance is CMX-Outdoor. The sheet prints NEMA WC-63.1 and ANSI/TIA-568.2-D Category 5e. It does not print a third-party verification line or an ISO/IEC line in the standards block that was read. The notes name T568A plug R301603 and T568B plug R301604, and a cold-bend line per UL 1581. 7923A lists UL temperature 75°C, operating -40°C to +75°C, installation -25°C to +75°C, and storage -25°C to +75°C. Stationary bend radius is 2.5 in (64 mm). Pull tension is 40 lbs (18 kg). Bulk weight is 25 lbs/1000ft. Suitability includes indoor, outdoor, sunlight resistance, and oil resistance, and does not list aerial. NEC / UL compliance is Article 800, CMR, CMX-Outdoor, CMG. CEC compliance is CMX-Outdoor; CMG. The sheet prints ANSI/TIA-568.2-D Category 5e, third-party performance verification Category 5e, and ISO/IEC 11801-1, IEC 61156-5. The notes say operating temperatures are subject to length de-rating and that the cable passes a -40C cold bend per UL 1581. Page revision is 0.540 on 7919A and 0.555 on 7923A, both dated 02-20-2026.
Black reels, and 7923A adds teal
As of November 5, 2026, 7919A variant rows include 7919A 0101000 black reel at 1,000 ft, 7919A 0102000 black reel at 2,000 ft, 7919A 0105000 black reel at 5,000 ft, and 7919A 0061000 blue reel at 1,000 ft. 7919A 01010000 is listed black and does not print a length in the row that was read. 7923A variant rows include 7923A 0101000 black, 7923A 0102000 black at 2,000 ft, 7923A 0061000 blue, 7923A 0081000 gray, 7923A 0021000 red, and 7923A 1NH1000 teal, each at 1,000 ft except the 2,000 ft black row. Footnote C, crate reel put-up, is on the rows that print it. Operating temperature on both sheets is still subject to the length de-rating note.
What to copy onto the cable line
- Part: 7919A or 7923A, from the sheet opened November 5, 2026.
- Pairs: 4 of 24 AWG solid bare copper, polyolefin.
- Shield: Beldfoil and a 24 AWG drain on 7919A. 7923A's read construction block has no outer-shield section, and bonded pair is yes.
- Jacket: PVC at 0.265 in, or PVC at 0.230 in.
- MSHA string: P-07-KA060004-MSHA, or P-07-KA060003-MSHA.
- UL temperature: 60°C, or 75°C. Operating range on both: -40°C to +75°C.
- Voltage: 300 V (CMR) and 300 V (CMX-Outdoor). NEC adds CMG on 7923A.
- Capacitance unbalance: 330 pF/ft, or 66 pF/ft.
Questions these sheets answer
Is one MSHA string enough for both parts?
7919A prints P-07-KA060004-MSHA, as of November 5, 2026. 7923A prints P-07-KA060003-MSHA. Both titles say MSHA CMR. The request uses the string on the sheet for the part being ordered.
Does the shared -40°C to +75°C line make the UL temperature 75°C?
Both operating cells print -40°C to +75°C, as of November 5, 2026. The UL temperature cell is 60°C on 7919A and 75°C on 7923A. Those cells stay separate.
Which sheet names a shield?
7919A's description names an overall Beldfoil shield, as of November 5, 2026. 7923A's description does not name a shield, and the construction block that was read has no outer-shield section.
Sources
Diameter, shield, MSHA string, UL temperature, and the voltage cells are from the Belden 7919A and 7923A technical data sheets. Both were opened November 5, 2026. Neither sheet names the other part number. Both titles say mining Cat 5e and MSHA CMR.