Belden 9843 at 120 Ohm or 7202A at 53 Ohm

Use 9843 for three 24 AWG pairs at 120 Ohm and 0.360 in. Use 7202A for the high-flex sheet at 53 Ohm, 0.336 in, and 1 million flex cycles.

Rust Belt Industrials · October 27, 2026 · 6 min read

On this page

Use Belden 9843 when the 3-pair 24 AWG cable has to be 120 Ohm. As of October 27, 2026, that sheet lists tinned copper 7x32, a PVC jacket of 0.360 in (9.14 mm), indoor use, and 1.54 A per conductor at 25°C. Use Belden 7202A when the 3-pair cable is the high-flex sheet at 53 Ohm. As of the same day, 7202A lists bare copper 41x40, a PVC jacket diameter of 0.336 in, 1 million flex cycles, and 12.6 A per conductor at 30°C. The April 2022 line card places 9843 in the light-industrial PVC rows and 7202A in the robotic high-flex rows, with the rating words CM, High Flex 1M 10XOD. Four pairs at 120 Ohm are 9844, on the 9843 and 9844 page.

Both sit on the RS-485 card, in different blocks

As of October 27, 2026, the line card lists 9843 as SF/UTP, 3 pair, 24 AWG, PVC, CMG, light industrial environment. It lists 7202A as SF/UTP, 3 pair, 24 AWG, industrial PVC, CM, High Flex 1M 10XOD, robotic, industrial, and other harsh environment. The 9843 sheet prints 300 V (CM), not the CMG cell. The 7202A voltage cell prints 300 V, and the NEC line prints Article 800, CM. The sheet's flex note is 1 million flex cycles based on proper installation techniques in a C-track cable guide. 10XOD is the line card's rating cell.

Tinned 7x32, or bare 41x40, plus an inner jacket on 7202A

As of October 27, 2026, 9843 insulation is polyethylene, 0.022 in (0.56 mm), nominal insulation diameter 0.068 in (1.7 mm), with three stripe pairs: blue, orange, and green. The shield is a 100% bi-laminate tape, a 24 AWG (7x32) tinned-copper drain, and a 90% tinned-copper braid. There is no inner jacket. 7202A insulation is foam polyethylene, 0.0115 in (0.292 mm), nominal insulation diameter 0.0555 in (1.41 mm). Colors are white and blue, white and orange, and white and green, written with an ampersand, not as stripe pairs. The shield is a 100% bi-laminate tape, a 24 AWG (41x40) tinned-copper drain, and an 85% tinned-copper braid. An inner PVC jacket is 0.0275 in (0.699 mm) with a nominal diameter of 0.275 in (6.99 mm). The outer PVC jacket is 0.045 in (1.1 mm). The outer-jacket diameter cell is 0.336 in. The overall-cable-diameter line prints 0.336 and does not print a unit. A ripcord cell says Yes.

9843 and 7202A rows from the sheets opened October 27, 2026.
Item98437202A
Line-card placeLight industrial, PVCRobotic high flex, industrial PVC
Conductor24 AWG 7x32 tinned copper24 AWG 41x40 bare copper
Impedance120 Ohm53 Ohm
Current1.54 A per conductor at 25°C12.6 A per conductor at 30°C
Jacket diameter cell0.360 in (9.14 mm)0.336 in
Inner jacketNot printed0.275 in (6.99 mm)
Flex noteNot printed1 million flex cycles
UL temperature80°C60°C

Copy the Ohm cell with the part number

As of October 27, 2026, 9843 lists conductor DCR of 24 Ohm/1000ft, capacitance of 12.8 pF/ft (42.0 pF/m) conductor to conductor and 23 pF/ft (75 pF/m) conductor to other, impedance of 120 Ohm, delay of 1.6 ns/ft, velocity of 66%, and insertion loss of 0.6 dB/100ft at 1 MHz. Outer-shield DCR is 2.3 Ohm/1000ft (7.5 Ohm/km). Voltage is 300 V (CM) and 30 V (UL AWM 2919). AWM compliance is AWM 2919. 7202A lists conductor DCR of 28.8 Ohm/1000ft, capacitance of 15 pF/ft (49 pF/m) conductor to conductor and 27 pF/ft (89 pF/m) conductor to other, impedance of 53 Ohm, and velocity of 72%. Outer-shield DCR is 2.57 Ohm/1000ft (8.43 Ohm/km). The voltage cell is 300 V. The sheet does not print AWM 2919, a delay cell, or an insertion-loss table. Other-standard compliance says RS Type: 232/485. Applications say Flex Data, RS232, RS485.

The current cells use different temperatures, as of October 27, 2026. 9843 is 1.54 A per conductor at 25°C. 7202A is 12.6 A per conductor at 30°C. Copy each cell with its temperature.

Indoor only on 9843, oil and a flex count on 7202A

As of October 27, 2026, 9843 lists UL temperature 80°C, operating temperature -30°C to +80°C, and suitability indoor. Bend radius is 3.75 in (95.3 mm), stationary and installation. Maximum pull tension is 105.5 lbs (47.85 kg). Weight is 62 lbs/1000ft. Flammability is UL 1685 UL Loading and IEC 60332-1-2. CPR is Euroclass Eca and UKCA Class Eca. The sheet does not print a flex-cycle count. 7202A lists UL temperature 60°C and operating temperature -20°C to +60°C. Stationary bend is 3.36 in (85.3 mm). Installation bend is 3.36 in, and that cell does not print millimeters. Maximum pull tension is 83 lbs (38 kg). Weight is 60 lbs/1000ft. Suitability lists Indoor/Outdoor, Indoor, Outdoor, and Oil Resistance. Flammability is UL1685 UL Loading. NEC compliance is Article 800, CM. CEC compliance is CM. The sheet does not print a CPR class or a UKCA line. The flex note is 1 million cycles in a C-track. Page revision is 0.404, dated 09-07-2025. Put-ups are green X4P reels 7202A X4P500 at 500 ft and 7202A X4P1000 at 1,000 ft, both with footnote C, crate reel put-up.

What to copy onto the cable line

  • Part: 9843 or 7202A, from the sheet opened October 27, 2026.
  • Impedance: 120 Ohm, or 53 Ohm.
  • Conductor: 24 AWG 7x32 tinned copper, or 24 AWG 41x40 bare copper.
  • Diameter: 0.360 in (9.14 mm), or the 0.336 in outer-jacket cell. Record the 0.275 in inner jacket if the part is 7202A.
  • Current: 1.54 A per conductor at 25°C, or 12.6 A per conductor at 30°C.
  • Flex: 1 million cycles, only on the 7202A note. The 10XOD words are the April 2022 line card.

9843 or 7202A note

Copy the impedance cell with the part number.

This prepares a request. It does not send one.

Questions these sheets answer

Does the RS-485 line card make 7202A a 120 Ohm cable?

The line card lists both under RS-485, as of October 27, 2026. 9843's impedance cell is 120 Ohm. 7202A's impedance cell is 53 Ohm. The card places them in the family. The sheet still chooses the Ohm value.

Which 7202A diameter is the outer jacket?

The outer-jacket diameter cell is 0.336 in, as of October 27, 2026. The inner jacket is 0.275 in (6.99 mm). The overall-diameter line prints 0.336 without a unit. Copy the outer-jacket cell when the request asks for the finished diameter, and name the inner jacket separately.

Where does 10XOD come from?

10XOD is on the April 2022 line card, in the 7202A rating cell, opened October 27, 2026. The 7202A sheet prints 1 million flex cycles and the bend cells above. It does not print 10XOD.

Sources

Impedance, conductor, diameter, current, and the flex note are from the Belden 9843 and 7202A technical data sheets. The light-industrial and robotic rows, including CMG on 9843 and High Flex 1M 10XOD on 7202A, are from the Belden RS-485 line card dated April 2022. All three were opened October 27, 2026. 7203A was opened and is not the comparison on this page, because its electrical table does not print an impedance cell.