Power connections
Busbar Joint Overlap: Storm's Five-Times Note or PrismaSeT I
Storm's jointing article uses five times the bar thickness. Schneider's PrismaSeT I FAQ uses five times for 5 mm copper and three times for 10 mm copper.
On this page
Use Storm's jointing article when the drawing is following that article's streamline note. Opened October 24, 2026, the article says the consequences of the streamline effect fall off rapidly once the overlap length is five times the thickness of the busbar, and that the overlap needed for bolting or clamping is usually at least that much. Use Schneider's PrismaSeT I FAQ when the joint is in that panel line. Opened the same day, the FAQ says a 5 mm copper busbar uses 5 times the thickness of the secondary busbars, and a 10 mm copper busbar uses 3 times the thickness of the secondary busbars. The FAQ also says IEC 61439 does not suggest an overlap dimension, and that the temperature-rise test is the proof of joint resistance for PrismaSeT I. The custom busbar request is where the overlap length goes once the drawing has named the sentence.
Storm's article ties five times thickness to the streamline effect
Storm describes a bolted joint as an overlap with bolts through holes, and flat washers under both the bolt head and the nut. A clamped joint also starts with an overlap, and the clamps sit around the joint. The article, opened October 24, 2026, says the streamline effect falls off rapidly at an overlap of five times the thickness, and that bolting or clamping usually needs at least that much overlap in practice. The article states the multiple and leaves the millimeter result to the drawing. A PrismaSeT I joint uses the Schneider rows below.
The same article says analysis shows bolts in a straight line, such as two rows of two or three bolts, disturb the current path less than staggered bolts. It says the actual contact area of a joint that looks flat is only about 1% of the overlap area, and that contact resistance falls as pressure rises until a point of diminishing returns. For a bolted joint, it says more bolts and large, thick, non-deforming washers spread the load. For a clamp, it says the pressure at the overlap depends on the rigidity of the clamps, and that clamps across wider bars may not provide that rigidity. It also says clamp plates have to be thick enough to pass the pressure without flexing, and it names ribbed clamp surfaces as one way to do that.
Storm says a Belleville washer used with the flat washer can reduce bolt tension if differential expansion between the bolt and the bar increases that tension. The article, opened October 24, 2026, lists bolt materials that include galvanized steel, copper alloy, high tensile steel, stainless steel, and aluminum bronze. Torque, washer part number, and stack height stay with the drawing.
PrismaSeT I prints two multiples, by copper thickness
The Schneider FAQ is titled for recommended overlap distance for busbar joints in PrismaSeT I. The design-rule lines, as opened October 24, 2026, are: 5 mm copper busbars, 5 times the thickness of the secondary busbars; 10 mm copper busbars, 3 times the thickness of the secondary busbars. The FAQ states those multiples and leaves the finished millimeter to the drawing. It says IEC 61439 does not suggest what the overlap dimension should be, and that all the joints in PrismaSeT I are validated by temperature-rise test to IEC 61439-1 and IEC 61439-2. That temperature-rise sentence is the FAQ's proof for PrismaSeT I.
| Page | When it applies | Overlap sentence | Still supplied by the drawing |
|---|---|---|---|
| Storm jointing article | A joint following that article's streamline note | Five times the busbar thickness, and usually at least that much for bolting or clamping | Torque, washer part number, and the finished millimeter |
| Schneider PrismaSeT I FAQ | A joint in PrismaSeT I | 5 mm copper: 5 times the secondary-busbar thickness. 10 mm copper: 3 times the secondary-busbar thickness. | The finished millimeter. The FAQ says IEC 61439 does not suggest an overlap dimension. |
Bolted and clamped joints both start with an overlap on the Storm page
Storm's bolted joint needs holes, so the fabrication drawing names the hole pattern as well as the overlap. The clamped joint, on that article, uses clamps around the overlap. The article says that joint needs more space than the bolted joint, and that clamp rigidity is part of the pressure. Riveted joints are described as the bolted hole pattern with rivets in place of bolts. The article says rivets are harder to adjust after installation. Soldered or brazed joints, on the same page, also begin with an overlap.
A flexible link at a joint that moves is a different part from this overlap. The flexible busbar page is where an EMS expansion busbar or a Flexibar stack is named. Overlap length on a rigid bolted joint does not select that flexible part.
What to copy onto the joint line
- Which sentence: Storm's five-times note, or a PrismaSeT I row, as opened October 24, 2026.
- Bar thickness, and, for PrismaSeT I, whether the row is the 5 mm line or the 10 mm line.
- Secondary-busbar thickness, when the Schneider line is the one in use.
- Joint type: bolted with holes, clamped without holes in the bar, or another type the drawing already shows.
- Washer note. Storm names flat washers on both sides, and a Belleville washer only as the expansion case, without a torque.
- Temperature-rise test reference only when the joint is the PrismaSeT I case the FAQ describes.
Questions the two pages answer
Do both pages use five times thickness for every bar?
Storm's streamline note is five times the thickness. Schneider's 5 mm copper row is also five times the secondary thickness. Schneider's 10 mm copper row is three times the secondary thickness. A 10 mm PrismaSeT I bar does not inherit Storm's five-times sentence from this page.
Does IEC 61439 set the overlap?
Schneider's FAQ says IEC 61439 does not suggest the overlap dimension, and that the temperature-rise test to IEC 61439-1 and IEC 61439-2 is what validates the PrismaSeT I joints. The IEC text itself was not opened.
Where is the bolt torque?
Neither page prints one. Storm names the Belleville washer as a way to limit bolt tension when expansion raises it, and it leaves the torque number off the article.
Sources
The five-times streamline note, the bolt-pattern comment, the contact-area sentence, the washer description, and the bolted, clamped, riveted, and brazed joint descriptions are from Storm's jointing article. The 5 mm and 10 mm rows, the IEC 61439 sentence, and the temperature-rise sentence are from Schneider's PrismaSeT I FAQ. Both were opened October 24, 2026.