Skip to the guide

Liquid cooling

EPDM vs FKM Seals for DOWFROST LC

Dow's wetted-materials list allows EPDM to at least 75°C and cautions some FKM compositions above 40°C. Everis LQ4 prints EPDM on the materials block and still names FKM as an option.

Rust Belt Industrials · October 23, 2026 · 5 min read

On this page

For DOWFROST LC, use EPDM when the design stays inside the wetted-materials line Dow prints for that elastomer: acceptable up to at least 75°C, as of the engineering guide opened October 23, 2026. Treat FKM as the caution line on that same list: some compositions are not recommended above 40°C. Everis LQ4, opened the same day, prints EPDM in the materials block and says in the product text that EPDM and FKM seals are standard options for glycol/water or dielectric coolants. The coupling page does not copy Dow's 75°C or 40°C lines onto a seal suffix. The fluid line and the coupling line both belong on the request.

What the DOWFROST LC list prints

The guide's wetted-materials list covers DOWFROST LC 25 and DOWFROST LC 55 together. Ethylene propylene diene monomer (EPDM) is acceptable up to at least 75°C. Fluoroelastomer (FKM) carries a caution that some compositions of this polymer are not recommended above 40°C. A footnote says initial data suggests peroxide-cured EPDM is more robust than sulfur-cured EPDM. The list does not name a coupling suffix, and it does not split LC 25 from LC 55. Freeze point for those two fluids is on the LC 25 and LC 55 page.

Section 3.3 of the same guide says a DECS fluid has to show long-term compatibility with elastomers and polymers up to bulk fluid temperatures of 90°C (194°F), and that the component material supplier verifies the specific elastomer or plastic before use. It also says substantial variation exists for specific elastomers. The 75°C and 40°C lines are the list. The 90°C sentence is the verification condition, not a third rating that replaces those lines. Metals on the same list, including brass with less than 15 percent zinc, copper, and solution-treated passivated stainless steel, are acceptable up to at least 90°C. Those metal lines are not seal ratings.

Elastomer rows from the DOWFROST LC wetted-materials list, opened October 23, 2026. The guide says the component supplier still verifies the specific material.
Material on the listLine the list printsWhat the list does not name
EPDMAcceptable up to at least 75°C.A coupling suffix, and a split between LC 25 and LC 55.
FKMCaution: some compositions are not recommended above 40°C.Which compositions, and a coupling catalog code.
Peroxide-cured EPDM, footnoteInitial data suggests it is more robust than sulfur-cured EPDM.A temperature of its own.

What Everis LQ4 prints on the same day

The LQ4 product text says EPDM and FKM seals are standard options for compatibility with glycol/water or dielectric coolants. The materials block prints Seals: EPDM. The seal-option filter on the page also shows EPDM. Pressure on that page is vacuum to 120 psi, 8.3 bar. Temperature range is 0°F to 240°F (-17°C to 115°C). The materials block does not attach the 75°C or 40°C fluid lines to those seals. Tube size and series, LQ4 versus LQ6, are on the series page. The -40°F operating extension is a different suffix question, on the FLS page.

The coupling high end is 115°C. Dow's EPDM line is 75°C. A loop that uses the coupling's full 115°C high end is above the EPDM line on the fluid list. Dow's FKM caution starts above 40°C, which is also below 115°C. The two temperatures answer different questions: 0°F to 240°F is the coupling range on the LQ4 page, and 75°C and 40°C are elastomer lines for the fluid. Put both on the request when both apply, and leave the suffix for the coupling maker to confirm when the materials block shows EPDM and the product text also names FKM.

Which seal line matches the fluid temperature

At a bulk fluid temperature of 40°C or below, both rows on Dow's list are still inside the printed limits: EPDM is acceptable up to at least 75°C, and the FKM caution is about compositions above 40°C. At a bulk temperature above 40°C and up to 75°C, the EPDM line still reads acceptable and the FKM line is already in the caution. Above 75°C, the EPDM line as printed has been passed, and section 3.3 still requires the component supplier to verify the material. The coupling page does not add a third temperature for that case.

Glycol/water and dielectric coolant appear in one CPC sentence covering both EPDM and FKM. Dow's list is for DOWFROST LC, which is the inhibited propylene glycol fluid in that guide. A dielectric coolant that is not DOWFROST LC does not inherit the 75°C and 40°C lines. Name the fluid. LC 25 and LC 55 share the wetted-materials list in the guide that was opened.

What to write on the seal line

  • Fluid: DOWFROST LC 25 or DOWFROST LC 55, if that is the coolant.
  • Elastomer row: EPDM at the 75°C line, or FKM at the 40°C caution, from the guide opened October 23, 2026.
  • Cure, if the footnote matters: peroxide-cured EPDM or sulfur-cured EPDM. The footnote does not add a temperature.
  • Coupling: Everis LQ4, with the materials block reading EPDM and the product text also naming FKM.
  • Coupling temperature range being used, inside or outside 0°F to 240°F.
  • The confirmation still owed by the seal supplier, which section 3.3 assigns to that supplier.

EPDM or FKM seal note

Copy the fluid row and the seal name from the coupling page.

This prepares a request. It does not send one.

Questions these two pages answer

Does LQ4 assign FKM to dielectric coolant and EPDM to glycol?

The product text puts EPDM and FKM in one sentence for glycol/water or dielectric coolants. It does not give one seal to one fluid. Dow's list is the place the 75°C and 40°C lines are printed, and that list is for DOWFROST LC.

Is 240°F the EPDM limit?

240°F (115°C) is the top of the LQ4 temperature range. Dow's EPDM line is 75°C. They are two sentences from two pages. A request can carry both and still ask the coupling maker which suffix matches the elastomer row.

Does the peroxide-cured footnote raise the EPDM temperature?

The footnote says initial data suggests peroxide-cured EPDM is more robust than sulfur-cured EPDM. It does not print a temperature above 75°C. The 75°C line stays with EPDM as a family on that list.

Sources

The 75°C EPDM line, the 40°C FKM caution, the peroxide-cured footnote, the 90°C (194°F) verification sentence, and the metal lines at 90°C are from the DOWFROST LC engineering and operating guide. The LQ4 seal sentence, the materials block, the vacuum-to-120 psi rating, and 0°F to 240°F are from the CPC Everis LQ4 page. Both were opened October 23, 2026.