Power connections
Hussey Silver Flash or Tin-Plated Busbar
Use silver flash for the finishes sheet's sliding-contact and high-temperature line, at 72 inch to 240 inch. Use tin-plated bar for the humid and sulfur line, at 72 inch to 144 inch.
On this page
Use Hussey silver flash when the finishes sheet's sliding-contact and high-temperature line is the match. As of October 28, 2026, that sheet lists silver-flash lengths of 72 inch to 240 inch, and the copper busbar page lists the same 72 inch to 240 inch. Use Hussey tin-plated bar when the sheet's humid, sulfur, and sheltered-outdoor line is the match. As of the same day, the finishes sheet and the busbar page both list tin-plated lengths of 72 inch to 144 inch. Bare copper on the finishes sheet is the dry indoor line, and it has no plated-length row. Alloy choice for rolled and extruded bar stays on the C110 and C102 page.
The finishes sheet assigns a condition to each column
The finishes sheet opened October 28, 2026 has three columns: bare copper, tin-plated, and silver-plated. Bare copper is labeled mill finish, no plating. The reasons on that column are full copper conductivity with no plating layer at the joint, and welded, brazed, or compound-treated connections. The fit line is dry, temperature-controlled indoor service, grounding systems, and fabricated assemblies where joints are prepared and sealed. A later line on the same sheet says controlled indoor air and prepared or permanent joints point to bare copper.
Tin-plated is labeled matte plate. The reasons on that column are sealing the copper against oxidation, holding joint resistance steady for the service life, resistance to humid and sulfur-bearing atmospheres, a soft deposit that fills surface irregularities, reduction of the galvanic couple at copper-to-aluminum interfaces, and solderability. The fit line is low-voltage distribution and panelboards, busway, grounding and bonding, and industrial and sheltered outdoor environments. A later line says moisture, sulfur, dissimilar-metal interfaces, and long unattended service point to tin-plated bar. Silver-plated is labeled silver flash. The reasons on that column are low, stable joint resistance, silver oxide that stays conductive, and high operating temperatures. The fit line is switchgear main bus, breaker stabs and racking contacts, high-current data center distribution, and micro-ohm critical joints. A later line says sliding or racking contacts, high temperatures, and the highest continuous current point to silver-plated bar.
The same sheet marks relative cost with one dollar sign on bare copper, two on tin-plated, and three on silver-plated, as of October 28, 2026. The sheet names Leetsdale, PA and Eminence, KY. It does not print a plating thickness in microinches.
Plated length is a separate line from the 396 inch bar length
As of October 28, 2026, the finishes sheet and the copper busbar page both list silver flash at 72 inch to 240 inch and tin-plated bar at 72 inch to 144 inch. A bar that needs silver and is longer than 240 inch, or tin and longer than 144 inch, is outside those plated-length lines. Overall bar length on both pages is up to 396 inch. The finishes sheet prints that length as 396 inch (33 ft). The busbar page prints 396 inch and does not add the foot figure. Thickness on both pages is 0.050 inch to 2.00 inch. Width on the busbar page is 0.500 inch to 12.00 inch. Width on the finishes sheet is 0.50 inch to 12.00 inch. The busbar page also lists coils at 350 inch maximum PIW and edge contours of square corners, rounded corners, and full rounded edge. The finishes sheet lists the same three edge contours.
| Finish | Condition on the finishes sheet | Plated length | Relative-cost mark |
|---|---|---|---|
| Bare | Dry indoor service, prepared joints | No plated-length row | One dollar sign |
| Tin-plated | Humid or sulfur atmospheres, sheltered outdoor | 72 inch to 144 inch | Two dollar signs |
| Silver flash | Sliding contacts, high temperature, high current | 72 inch to 240 inch | Three dollar signs |
The what-is page names a second pair of application lists
Hussey's what-is page, opened October 28, 2026, names tin-plated copper busbar for protection from oxidation and for utilities, renewable energy, marine, and outdoor electrical equipment. It names silver-plated copper busbar for high-temperature or high-current applications such as switchgear, power generation, and industrial equipment. Those lists are not the same sentences as the finishes sheet. The finishes sheet's tin line says sheltered outdoor and sulfur-bearing atmospheres. The what-is page's tin line says marine and outdoor equipment. The finishes sheet's silver line names breaker stabs, racking contacts, and data center distribution. The what-is page's silver line names power generation and industrial equipment. Copy the list from the page you are using. A third sentence on the what-is page says tin-copper or silver-copper plating can protect connection surfaces from oxidation and corrosion. It does not assign one plating to one environment by itself.
What to copy onto the finish line
- Finish: bare, tin-plated, or silver flash, from the finishes sheet opened October 28, 2026.
- Condition: the column you matched, kept separate from the what-is page's application list.
- Plated length: 72 inch to 144 inch for tin, or 72 inch to 240 inch for silver flash.
- Bar size: thickness 0.050 inch to 2.00 inch, width, and overall length up to 396 inch.
- Alloy: from the busbar page, on the C110 and C102 guide, when the process is rolled or extruded.
Questions these Hussey pages answer
Can a 200 inch tin-plated bar use the silver length line?
Tin-plated length on both Hussey pages is 72 inch to 144 inch, as of October 28, 2026. Silver flash is 72 inch to 240 inch. A 200 inch plated length is inside the silver line and outside the tin line. The finish column still has to match the condition. Length does not choose the plating.
Does the what-is page replace the finishes sheet?
The what-is page names outdoor and marine equipment for tin, and high-temperature or high-current work for silver, as of October 28, 2026. The finishes sheet names the humid and sulfur line for tin and the sliding-contact line for silver, and it is the page that prints the plated lengths next to those columns. Keep the two lists apart.
Do the dollar signs set a price?
The finishes sheet prints one, two, and three dollar signs as relative-cost marks, as of October 28, 2026. It does not print a price per pound or a plating thickness.
Sources
The condition columns, the relative-cost marks, the plated lengths, and the Leetsdale and Eminence line are from Hussey's busbar finishes sheet. The matching plated lengths, the 0.050 inch to 2.00 inch thickness, and the 396 inch bar length are also on Hussey's copper busbar page. The oxidation and high-temperature application lists are from Hussey's what-is page. All three were opened October 28, 2026.