Industrial networking
Belden 1334A PVC at 5.2 A or 2100A TPE at 8.7 A
Use 1334A for the Type A industrial PVC row at 0.287 in and 5.2 A. Use 2100A for the Type A extra-rugged XLPE row, TPE jacket, at 0.319 in and 8.7 A.
On this page
Use Belden 1334A when the one-pair 18 AWG Type A cable is the PVC industrial row. As of November 6, 2026, that sheet lists a jacket of 0.287 in (7.29 mm), a 65% tinned-copper braid, 5.2 A per conductor with no temperature in that cell, conductor DCR of 7.2 Ohm/1000ft, and 100 Ohm. Use Belden 2100A when the cable is the extra-rugged row. As of the same day, that sheet lists a TPE jacket of 0.319 in (8.10 mm), 8.7 A per conductor with no temperature in that cell, conductor DCR of 5.86 Ohm/1000ft (19.2 Ohm/km), and 100 Ohm. The category places both under 300 V Type A PLTC/ITC-ER, 18 AWG, one pair: 1334A on Standard Industrial-grade, and 2100A on Extra Rugged (XLPE Material). The 600 V extra-rugged row is on the 2100A and 2118A page.
PVC and a 65% braid, or TPE over an XLPE cell
As of November 6, 2026, 1334A's description says PO insulation, an overall Beldfoil plus a tinned-copper braid, and an orange PVC jacket, CMG. The insulation cell says polypropylene, colors blue and orange, and it does not print a thickness. The shield is a 100% bi-laminate tape and a tinned-copper braid at 65%. The jacket cell is PVC, 0.065 in (1.7 mm), nominal diameter 0.287 in (7.29 mm), with a ripcord. 2100A's title and description say XLPO insulation and a TPE jacket, CMG. The insulation cell says XLPE, cross-linked polyethylene, thermoset, colors blue, orange, and numbered. The inner-shield block is a 100% bi-laminate tape and a tinned-copper line that does not print a coverage percent. The jacket cell is TPE, nominal diameter 0.319 in (8.10 mm), with a ripcord, and it does not print a thickness. Neither sheet names the other part number.
| Item | 1334A | 2100A |
|---|---|---|
| Category row | Type A, standard industrial-grade | Type A, extra rugged, XLPE |
| Jacket | PVC, 0.287 in | TPE, 0.319 in |
| Insulation cell | Polypropylene | XLPE, thermoset |
| Braid | 65% tinned copper | No coverage percent on the tinned-copper line |
| Current | 5.2 A, no temperature | 8.7 A, no temperature |
| Conductor DCR | 7.2 Ohm/1000ft | 5.86 Ohm/1000ft |
| UL temperature | 90°C | 90°C wet/dry |
| Voltage cell | 300 V RMS | 300 V |
100 Ohm on both, at 5.2 A or 8.7 A
As of November 6, 2026, 1334A lists capacitance conductor to shield of 45 pF/ft (150 pF/m), unbalance of 1.2 pF/ft, impedance of 100 Ohm, and velocity of 66%. Outer-shield DCR is 3.8 Ohm/1000ft (12 Ohm/km). Insertion loss is 0.069 dB/100ft with no frequency on that line. 2100A lists capacitance of 22 pF/ft (72 pF/m) under a conductor-to-shield header, unbalance of 1.2 pF/ft, impedance of 100 Ohm, inductance of 0.22 µH/ft (0.72 µH/m), and velocity of 64%. The electrical block does not print an outer-shield DCR. Insertion loss is 0.08 dB/100ft with no frequency on that line. Voltage is 300 V RMS on 1334A and 300 V on 2100A. NEC / UL compliance is Article 725, Article 727, Article 800, CMG, ITC, PLTC on both. 2100A also lists AWM I A/B II A/B and C22.2 #230 Type TC, C22.2 #239 Type CIC. CEC compliance is CMG on 1334A and CIC, TC on 2100A.
UL 90°C on both, and the operating high is not the same cell
As of November 6, 2026, 1334A lists UL temperature 90°C and operating temperature -40°C to +105°C. Bend radius is 3.37 in (85.6 mm), stationary and installation. Pull tension is 44.8 lbs (20.3 kg). Bulk weight is 60 lbs/1000ft. 2100A's temperature headers are UL Temperature, Operating, and Installation. The UL cell is 90°C wet/dry. The string that lines up with the Operating header is -40°C to +90°C. The installation cell is -25°C. The same row also prints -25°C cold impact and -55°C cold bend. The mechanical text then goes to pull tension and does not print a bend-radius cell. Pull tension is 57 lbs (26 kg). Bulk weight is 51 lbs/1000ft (76 kg/km). Suitability on 1334A is indoor, outdoor, sunlight resistance, UV resistance, and oil resistance twice. Suitability on 2100A is indoor, outdoor, sunlight resistance, UV resistance, and oil resistance once. Flammability on 1334A includes 1202. Flammability on 2100A is UL1685 FT4 Loading and IEC 60332-3-24.
3,280 ft on 1334A, and 5,000 ft light blue on 2100A
As of November 6, 2026, 1334A variant rows are 1334A 0061000 light blue at 1,000 ft, 1334A 0063280 light blue at 3,280 ft, 1334A 0031000 orange at 1,000 ft, and 1334A 0033280 orange at 3,280 ft, footnote C. 2100A variant rows are 2100A 0065000 light blue at 5,000 ft, 2100A 0031000 orange at 1,000 ft, and 2100A 0035000 orange at 5,000 ft. That table does not print footnote C and does not print a 1,000 ft light blue row. Page revision is 0.569, dated 02-20-2026, on 1334A, and 0.662, dated 10-30-2026, on 2100A. 2100A's standards block that was read does not print ISA/SP-50 Type A. The category page is the page that calls this cable extra rugged XLPE under Type A. The foil-only flexible cable at 0.280 in is on the 3076F and 1334A page.
What to copy onto the cable line
- Part: 1334A or 2100A, from the sheet opened November 6, 2026.
- Category row: Type A standard industrial-grade, or Type A extra rugged, XLPE material.
- Jacket: PVC at 0.287 in with a 65% braid, or TPE at 0.319 in.
- Insulation cell: polypropylene, or XLPE thermoset. 2100A's title says XLPO.
- Impedance: 100 Ohm. Current: 5.2 A, or 8.7 A. Neither 1334A current cell nor the 2100A current cell prints a temperature.
- Conductor DCR: 7.2 Ohm/1000ft, or 5.86 Ohm/1000ft.
- Voltage cell: 300 V RMS, or 300 V. NEC on both includes CMG, ITC, and PLTC.
- UL temperature: 90°C, or 90°C wet/dry. 1334A's operating high is +105°C. 2100A's operating string is -40°C to +90°C.
Questions these pages answer
Does the insulation cell say XLPO?
2100A's title and description say XLPO, as of November 6, 2026. The insulation cell says XLPE, cross-linked polyethylene, thermoset. The request can carry both strings, each tied to the line that printed it.
Does 8.7 A include 25°C?
2100A's current cell is 8.7 A per conductor, as of November 6, 2026, and it does not print a temperature. 1334A's current cell is 5.2 A per conductor and also does not print a temperature. 25°C stays off both cells.
Which bend radius is on 2100A?
The 2100A mechanical text that was read does not print a bend-radius cell, as of November 6, 2026. It does print -55°C cold bend on the temperature row. 1334A's bend radius is 3.37 in, stationary and installation.
Sources
Jacket, current, DCR, and temperature are from the Belden 1334A and 2100A technical data sheets. The Type A row labels are from the Belden Foundation Fieldbus category. All three were opened November 6, 2026. Neither sheet names the other part number.