Belden 8761 PVC at 64 Ohm or 88761 FEP at 42 Ohm

Use 8761 for the PVC CM jacket at 0.175 in, 64 Ohm, and 6 A. Use 88761 for the FEP CMP jacket at 0.116 in, 42 Ohm, and 9 A. Each sheet names the other.

Rust Belt Industrials · November 3, 2026 · 5 min read

On this page

Use Belden 8761 when the one-pair 22 AWG cable is the PVC jacket listed CM. As of November 3, 2026, that sheet lists a nominal jacket diameter of 0.175 in (4.45 mm), characteristic impedance of 64 Ohm, 6 A per conductor at 30°C, and 300 V (CM) together with 300 V (UL AWM 2092). Use Belden 88761 when the cable is the FEP jacket listed CMP. As of the same day, that sheet lists a nominal jacket diameter of 0.116 in (2.95 mm), characteristic impedance of 42 Ohm, 9 A per conductor at 30°C, and 300 V (CMP). 8761's plenum-number cell names 88761, 87761, and 82761. 88761's non-plenum number is 8761. The two-pair PVC sheet is on the 8761 and 8723 page.

One pair, polyethylene and PVC, or FEP and FEP

As of November 3, 2026, both titles say 2 conductor, 22 AWG stranded tinned copper, and the construction element is one pair of 22 AWG 7x30. 8761 insulation is polyethylene, 0.017 in (0.43 mm), nominal insulation diameter 0.062 in (1.6 mm), colors black and clear. The shield is one 100% bi-laminate tape with a 22 AWG (7x30) tinned-copper drain. The jacket is PVC, 0.025 in (0.64 mm), nominal diameter 0.175 in (4.45 mm). 88761 insulation is FEP, 0.007 in (0.18 mm), nominal insulation diameter 0.042 in (1.1 mm), colors black and red. The shield is the same tape style with a 22 AWG (7x30) tinned-copper drain. The jacket is FEP, 0.014 in (0.36 mm), nominal diameter 0.116 in (2.95 mm). The colors and the insulation compound change with the part number.

8761 and 88761 rows from the technical data sheets opened November 3, 2026.
Item876188761
JacketPVC, 0.175 inFEP, 0.116 in
ColorsBlack, clearBlack, red
Impedance64 Ohm42 Ohm
Current6 A at 30°C9 A at 30°C
UL temperature60°C150°C
Operating range-20°C to +60°C-20°C to +150°C
Voltage300 V (CM), AWM 2092300 V (CMP)
Cross-referencePlenum numbers include 88761Non-plenum number 8761

64 Ohm and 6 A, or 42 Ohm and 9 A, both at 30°C

As of November 3, 2026, 8761 lists conductor DCR of 18.2 Ohm/1000ft, capacitance of 24 pF/ft (79 pF/m) and 47 pF/ft (150 pF/m), inductance of 0.2 µH/ft (0.66 µH/m), and impedance of 64 Ohm. The sheet does not print a velocity. Current is 6 A per conductor at 30°C. 88761 lists conductor DCR of 18.2 Ohm/1000ft, outer-shield DCR of 12.86 Ohm/1000ft (42.19 Ohm/km), capacitance of 35 pF/ft (110 pF/m) and 67 pF/ft (220 pF/m), inductance of 0.16 µH/ft (0.52 µH/m), and impedance of 42 Ohm. Current is 9 A per conductor at 30°C. 8761 does not print an outer-shield DCR. Voltage on 8761 is 300 V (CM) and 300 V (UL AWM 2092). AWM compliance is AWM 2092. NEC / UL compliance is Article 800, CM. 88761's voltage is 300 V (CMP). NEC / UL compliance is Article 800, CMP. 88761 does not print an AWM line.

88761 stays at -20°C on the operating low

As of November 3, 2026, 8761 lists UL temperature 60°C and operating temperature -20°C to +60°C. Bend radius is 1.8 in (46 mm). Pull tension is 27.3 lbs (12.4 kg). Bulk weight is 16 lbs/1000ft. Suitability is indoor. Flammability is UL 1685 UL loading and IEC 60332-1-2. 88761 lists UL temperature 150°C and operating temperature -20°C to +150°C. The applications line says extreme high and low temperature, chemical resistance, outdoor and burial. The operating cell still starts at -20°C. Suitability is indoor and outdoor. The suitability cell does not say burial. Bend radius is 1.2 in (30 mm). Pull tension is 27.3 lbs (12.4 kg). Bulk weight is 13 lbs/1000ft. Flammability is NFPA 262, UL 910 (Plenum), FT4, and IEC 60332-1-2. The notes say the cable is for indoor plenum environments and is also suitable for outdoor and underground applications, and they name Teflon as a DuPont trademark used under license. Page revision is 0.537, dated 02-20-2026, on 8761, and 0.588, dated 09-07-2025, on 88761.

Chrome on 8761, red lengths on 88761

As of November 3, 2026, 8761 variant rows include chrome reels at 500 ft (8761 060500) and 1,000 ft (8761 0601000, footnote C). 88761 variant rows are red and print a length: 88761 002100 at 100 ft, 88761 002500 at 500 ft, 88761 0021000 at 1,000 ft, and 88761 0025000 at 5,000 ft, with footnote C on the marked rows. 87761 and 82761 are the other names in 8761's plenum-number cell. Those sheets are on the 82761 and 88761 page and the 87761 and 88761 page.

What to copy onto the cable line

  • Part: 8761 or 88761, from the sheet opened November 3, 2026.
  • Pair: 1 of 22 AWG 7x30. Colors black and clear, or black and red.
  • Drain: 22 AWG (7x30) on the overall tape, on both sheets.
  • Jacket: PVC at 0.175 in, or FEP at 0.116 in.
  • Impedance: 64 Ohm, or 42 Ohm.
  • Current: 6 A at 30°C, or 9 A at 30°C.
  • Temperature: UL 60°C and operating -20°C to +60°C, or UL 150°C and operating -20°C to +150°C.
  • Listing: 300 V (CM) and AWM 2092, or 300 V (CMP).

8761 or 88761 note

Name the one-pair part and copy the jacket, impedance, and current from that sheet.

This prepares a request. It does not send one.

Questions these sheets answer

Does the FEP sheet keep 64 Ohm?

8761 prints 64 Ohm, as of November 3, 2026. 88761 prints 42 Ohm. The non-plenum number on 88761 is 8761. The Ohm cell still changes.

Does 88761 operate from -70°C?

88761's operating range is -20°C to +150°C, as of November 3, 2026. The applications line says extreme high and low temperature. The operating cell is the range to copy.

Which sheet prints AWM 2092?

8761 prints AWM 2092, as of November 3, 2026. 88761's compliance block has CMP and does not print an AWM line.

Sources

Jacket, impedance, current, temperature, and the cross-reference numbers are from the Belden 8761 and 88761 technical data sheets. Both were opened November 3, 2026. 82761 and 87761 were opened the same day for the pages linked above.