Skip to the guide

Industrial networking

Belden 8761 One Pair at 64 Ohm or 8723 Two Pair at 52 Ohm

Use 8761 for one 22 AWG pair, overall foil, and 64 Ohm. Use 8723 for two 22 AWG pairs, a foil on each pair, and 52 Ohm. Both sheets list the same application line and CM.

Rust Belt Industrials · October 29, 2026 · Updated November 3, 2026 · 6 min read

On this page

Use Belden 8761 when the cable is one 22 AWG pair with an overall foil and the impedance cell reads 64 Ohm. As of October 29, 2026, that sheet lists a PVC jacket of 0.175 in (4.45 mm), polyethylene insulation, 6 A per conductor at 30°C, and an operating range of -20°C to +60°C. Use Belden 8723 when the cable is two 22 AWG pairs with a foil on each pair and the impedance cell reads 52 Ohm. As of the same day, that sheet lists a PVC jacket of 0.160 in (4.06 mm), polypropylene insulation, 2.8 A per conductor at 25°C, and an operating range of -20°C to +75°C. Both sheets list CM and the same suitable-application sentence: low voltage analog signals, low voltage digital control, line level audio, computer communication, and panel wiring. Neither title says RS-485. A 120 Ohm RS-485 pair is 9841, on the 9841 and 9842 page.

Both sheets print the same application sentence, and the Ohm cells differ

The product title on 8761, as of October 29, 2026, is an electronic cable, 2 conductor 22 AWG stranded tinned copper, polyethylene insulation, overall Beldfoil shield, PVC jacket, CM. The product title on 8723 is an audio, control, and instrument cable, 22 AWG, 2 pair, polypropylene insulation, individual foil, PVC jacket, CM. The suitable-application cell on each sheet is the same list. That shared list is the reason these two part numbers sit on one request when the job is analog, digital control, audio, computer communication, or panel wiring. The impedance cell then picks the part: 64 Ohm on the one-pair sheet, 52 Ohm on the two-pair sheet. Neither cell prints a plus-or-minus tolerance. Neither cell prints 120 Ohm.

One overall foil at 0.175 in, or a foil on each pair at 0.160 in

As of October 29, 2026, 8761 lists one pair of 22 AWG 7x30 tinned copper. Insulation is polyethylene, 0.017 in (0.43 mm) thick, nominal insulation diameter 0.062 in (1.6 mm), colors black and clear. The shield is one 100% bi-laminate tape with a 22 AWG (7x30) tinned-copper drain. The jacket is PVC, 0.025 in (0.64 mm) thick, nominal diameter 0.175 in (4.45 mm). 8723 lists two pairs of 22 AWG 7x30 tinned copper. Insulation is polypropylene, 0.009 in (0.23 mm) thick, nominal insulation diameter 0.046 in (1.2 mm), colors black and red, and green and white. Each pair has a 100% bi-laminate tape, foil out, with a 24 AWG (7x32) tinned-copper drain. The jacket is PVC, 0.020 in (0.51 mm) thick, nominal diameter 0.160 in (4.06 mm). The two-pair jacket is the smaller of the two diameters on these sheets.

8761 and 8723 rows from the technical data sheets opened October 29, 2026.
Item87618723
Pairs1, 22 AWG2, 22 AWG
ShieldOverall foil, 22 AWG drainFoil on each pair, 24 AWG drain
JacketPVC, 0.175 inPVC, 0.160 in
Impedance64 Ohm52 Ohm
Current6 A at 30°C2.8 A at 25°C
Operating range-20°C to +60°C-20°C to +75°C
UL temperature60°C60°C
ListingCM, AWM 2092CM

64 Ohm and 52 Ohm, with the current tied to the temperature in the cell

As of October 29, 2026, 8761 lists nominal conductor DCR of 18.2 Ohm/1000ft, capacitance conductor to conductor of 24 pF/ft (79 pF/m), capacitance to the other conductors plus shield of 47 pF/ft (150 pF/m), inductance of 0.2 µH/ft (0.66 µH/m), and characteristic impedance of 64 Ohm. The current cell is 6 A per conductor at 30°C. The sheet does not print a velocity. 8723 lists nominal conductor DCR of 18.2 Ohm/1000ft, inner-shield DCR of 18.38 Ohm/1000ft (60.30 Ohm/km), capacitance of 33 pF/ft (110 pF/m) and 62 pF/ft (200 pF/m), inductance of 0.17 µH/ft (0.56 µH/m), velocity of 66%, and characteristic impedance of 52 Ohm. The current cell is 2.8 A per conductor at 25°C. The two current cells use different temperatures. 8723's high-frequency line prints 10 dB/100m and does not print a frequency. 8761 does not print an insertion-loss cell.

8761's UL voltage rating, as of October 29, 2026, is 300 V (CM) and 300 V (UL AWM 2092). NEC / UL compliance is Article 800, CM. AWM compliance is AWM 2092. CEC compliance is CM. Flammability is UL 1685 UL loading and IEC 60332-1-2. 8723's UL voltage rating is 300 V (CM). NEC / UL compliance is Article 800, CM. That sheet does not print an AWM line. Flammability is UL 1685 FT4 Loading and IEC 60332-1-2. Both print CPR Euroclass Eca and CPR UKCA Class Eca. 8723 also prints China RoHS II. Environmental suitability on both is indoor. Plenum numbers on 8761 are 88761, 87761, and 82761. Plenum numbers on 8723 are 82723, 87723, and 88723. Those 8761 and 8723 cells were read again on November 3, 2026, and they match this paragraph. The FEP sheets are on the 8761 and 88761 page and the 8723 and 88723 page. The other CMP jackets opened that day are on the 82761 and 88761 page and the 82723 and 88723 page. 87761 is on the 87761 and 88761 page. The 87723 technical-data URL did not return a data sheet on November 3, 2026, so this page does not assign 87723 a diameter or a listing.

UL temperature is 60°C on both, and 8723's operating high is 75°C

As of October 29, 2026, 8761 lists UL temperature 60°C and operating temperature -20°C to +60°C. Minimum bend radius is 1.8 in (46 mm) for stationary and installation. Maximum pull tension is 27.3 lbs (12.4 kg). Bulk weight is 16 lbs/1000ft. 8723 lists UL temperature 60°C and operating temperature -20°C to +75°C. The operating high and the UL temperature are different cells on that sheet. Bend radius is 1.6 in (41 mm). Pull tension is 42 lbs (19 kg). Bulk weight is 17 lbs/1000ft. Page revision is 0.537, dated 02-20-2026, on 8761, and 0.576, dated 02-20-2026, on 8723.

What to copy onto the cable line

  • Part: 8761 or 8723, from the sheet opened October 29, 2026.
  • Pairs: one 22 AWG pair, black and clear, or two 22 AWG pairs, black/red and green/white.
  • Shield: overall foil with a 22 AWG drain, or a foil and a 24 AWG drain on each pair.
  • Jacket: PVC at 0.175 in, or PVC at 0.160 in.
  • Impedance: 64 Ohm, or 52 Ohm.
  • Current: 6 A at 30°C, or 2.8 A at 25°C.
  • Temperature: UL 60°C with operating -20°C to +60°C, or UL 60°C with operating -20°C to +75°C.
  • Listing: CM and AWM 2092, or CM.

8761 or 8723 note

Name the 22 AWG part and copy the impedance, shield, and current from that sheet.

This prepares a request. It does not send one.

Questions these sheets answer

Does 64 Ohm stand in for a 120 Ohm RS-485 pair?

8761 prints 64 Ohm, and 8723 prints 52 Ohm, as of October 29, 2026. Neither title says RS-485. The 120 Ohm one-pair sheet is 9841.

Does 8723's UL cell say 75°C?

8723's UL temperature is 60°C, as of October 29, 2026. The operating range on that sheet is -20°C to +75°C. The two cells stay separate.

Which drain goes with 8723?

8723's drain is 24 AWG (7x32) tinned copper, one on each pair, as of October 29, 2026. 8761's drain is 22 AWG (7x30) tinned copper on the overall tape.

Sources

Pair count, shield, jacket, impedance, current, temperature, and listing are from the Belden 8761 and 8723 technical data sheets. Both were opened October 29, 2026, and again on November 3, 2026. Both print the same suitable-application sentence. 87723 was named on 8723 and was not opened.