Skip to the guide

Industrial networking

Belden 3077F at 100 Ohm or 3078F at 150 Ohm

Use 3077F for the Type B flexible row at 0.197 in, 100 Ohm, and UL 105°C. Use 3078F for the Type B high-speed row at 0.351 in, 150 Ohm, and UL 75°C. Both list 22 AWG and 2.5 A.

Rust Belt Industrials · November 6, 2026 · 5 min read

On this page

Use Belden 3077F when the 22 AWG fieldbus pair is the flexible row at 100 Ohm. As of November 6, 2026, that sheet lists a PVC jacket of 0.197 in (5.00 mm), 2.5 A per conductor with no temperature in the cell, UL temperature 105°C, and characteristic impedance of 100 Ohm. Use Belden 3078F when the row is the high-speed construction at 150 Ohm. As of the same day, that sheet lists a PVC jacket of 0.351 in (8.92 mm), the same 2.5 A with no temperature in the cell, UL temperature 75°C, and characteristic impedance of 150 Ohm. The category places both under 300 V Type B PLTC/ITC, 22 AWG, one pair: 3077F on Flexible, and 3078F on Flexible, High Speed. The 18 AWG Type A row at 100 Ohm is on the 3076F and 3077F page.

Polypropylene at 0.197 in, or foam polyethylene at 0.351 in

As of November 6, 2026, 3077F is one pair of 22 AWG 7x30 tinned copper. Insulation is polypropylene, 0.015 in (0.38 mm), colors blue and orange. The shield is a 100% bi-laminate tape and a 22 AWG (7x30) tinned-copper drain. The jacket is PVC, 0.037 in (0.94 mm), nominal diameter 0.197 in (5.00 mm). 3078F is one pair of 22 AWG 7x30 tinned copper. Insulation is foam polyethylene, 0.046 in (1.2 mm), colors blue and orange, with a note HDPE with skin. The shield is a 100% bi-laminate tape and a 20 AWG (7x28) tinned-copper drain. The jacket is PVC, 0.050 in (1.3 mm), nominal diameter 0.351 in (8.92 mm). 3078F's title says flexible high speed, CM, PLTC. 3077F's title says flexible, PLTC, ITC, CM. Neither sheet names the other part number, and neither standards block that was read prints the words Type B.

3077F and 3078F rows from the sheets and the category page opened November 6, 2026.
Item3077F3078F
Category rowType B, flexibleType B, flexible, high speed
JacketPVC, 0.197 inPVC, 0.351 in
InsulationPolypropylene, 0.015 inFoam polyethylene, 0.046 in
Impedance100 Ohm150 Ohm
Velocity66%78%
Current2.5 A, no temperature2.5 A, no temperature
UL temperature105°C75°C
Voltage cell300 V (CM, PLTC), 150 V (ITC)300 V (CM, PLTC)

The high-speed row is 150 Ohm, not 100 Ohm

As of November 6, 2026, 3077F lists conductor DCR of 17.1 Ohm/1000ft (56.1 Ohm/km), capacitance conductor to shield of 44 pF/ft (140 pF/m), unbalance of 1.2 pF/ft, impedance of 100 Ohm, inductance of 0.2 µH/ft (0.66 µH/m), and velocity of 66%. Outer-shield DCR is 11.4 Ohm/1000ft (37.4 Ohm/km). Insertion loss at 0.039 MHz is 0.14 dB/100ft. 3078F lists the same 17.1 Ohm/1000ft (56.1 Ohm/km), capacitance of 16 pF/ft (52 pF/m), unbalance of 0.46 pF/ft, impedance of 150 Ohm, inductance of 0.3 µH/ft (0.98 µH/m), and velocity of 78%. The electrical block does not print an outer-shield DCR. Insertion loss is 0.18 dB/100ft at 0.25 MHz, 0.26 dB/100ft at 0.625 MHz, 0.34 dB/100ft at 1.25 MHz, and 0.55 dB/100ft at 3.125 MHz. Voltage on 3077F is 300 V (CM, PLTC) and 150 V (ITC). Voltage on 3078F is 300 V (CM, PLTC). NEC / UL compliance on 3077F includes Article 727 and ITC. On 3078F it is Article 725, Article 800, CM, PLTC.

UL 105°C on the 100 Ohm sheet, UL 75°C on the 150 Ohm sheet

As of November 6, 2026, 3077F lists UL temperature 105°C and operating temperature -30°C to +105°C. The mechanical block does not print a bend radius. Pull tension is 27 lbs (12 kg). Bulk weight is 18 lbs/1000ft (27 kg/km). Suitability is outdoor and sunlight resistance. 3078F lists UL temperature 75°C and operating temperature -40°C to +75°C. The mechanical block does not print a bend radius. Pull tension is 32 lbs (15 kg). Bulk weight is 40 lbs/1000ft (60 kg/km). Suitability is outdoor and sunlight resistance. Flammability on 3077F is UL 1685 UL Loading and IEC 60332-1-2. Flammability on 3078F is UL 1685 UL Loading. CPR is Euroclass Eca on both. 3077F's notes say a CPE and low-smoke jacket is optional. 3078F's notes say a CPE and LSzH jacket is optional. Neither note names a part number. Page revision is 0.526 on 3077F and 0.523 on 3078F, both dated 02-20-2026.

Orange reels on both, and no light blue row

As of November 6, 2026, 3077F lists 3077F 003500 orange at 500 ft and 3077F 0031000 orange at 1,000 ft, footnotes C and N. Footnote N says the final put-up length may vary from 0% to +10% from the length shown. 3078F lists 3078F 003500 orange at 500 ft, 3078F 0031000 orange at 1,000 ft, and 3078F 0032500 orange at 2,500 ft, footnote C. Neither table prints a light blue row. The light blue PROFIBUS PA put-up on this site is 3076F 0061000, on the gauge page linked above. A 150 Ohm PROFIBUS DP cable is a different part family from this 150 Ohm high-speed fieldbus row.

What to copy onto the cable line

  • Part: 3077F or 3078F, from the sheet opened November 6, 2026.
  • Category row: 300 V Type B, flexible, or 300 V Type B, flexible, high speed.
  • Gauge: 22 AWG 7x30. Colors: blue and orange.
  • Jacket: PVC at 0.197 in, or PVC at 0.351 in.
  • Insulation: polypropylene at 0.015 in, or foam polyethylene at 0.046 in with the HDPE-with-skin note.
  • Impedance: 100 Ohm, or 150 Ohm. Velocity: 66%, or 78%.
  • Current: 2.5 A per conductor, with no temperature in either cell.
  • UL temperature: 105°C and operating -30°C to +105°C, or 75°C and operating -40°C to +75°C.

3077F or 3078F note

Name the Type B row. Flexible is 100 Ohm. High speed is 150 Ohm.

This prepares a request. It does not send one.

Questions these pages answer

Does Type B keep 100 Ohm on the high-speed row?

3077F prints 100 Ohm, as of November 6, 2026. 3078F prints 150 Ohm. The category still places both on the 300 V Type B block. The impedance cell is what the request copies.

Does the 3078F sheet print Type B?

3078F's title says flexible high speed, as of November 6, 2026. The standards block that was read does not print Type B. The category page is the page that places 3078F on the Type B high-speed row.

Which temperature is on the 2.5 A cell?

Neither current cell prints a temperature, as of November 6, 2026. The UL cells are separate: 105°C on 3077F and 75°C on 3078F.

Sources

Impedance, diameter, current, and temperature are from the Belden 3077F and 3078F technical data sheets. The Type B row labels are from the Belden Foundation Fieldbus category. All three were opened November 6, 2026. Neither sheet names the other part number.