Industrial networking
Belden 3094A at 75 Ohm or 3095A at 100 Ohm
Use 3094A for the RG-11 PVC coax at 75 Ohm, 0.407 in, and 300 V (CMR, CMG). Use 3095A for the RG-11 PVDF coax at 100 Ohm ± 3 Ohm, 0.387 in, and CMP. Each sheet names the other.
On this page
Use Belden 3094A when the RG-11 ControlBus coax is the 75 Ohm PVC sheet. As of November 3, 2026, that sheet lists a jacket of 0.407 in (10.3 mm), 14 AWG solid bare copper covered steel, conductor DCR of 11.5 Ohm/1000ft, and 300 V (CMR, CMG). Use Belden 3095A when the coax that names 3094A as its non-plenum number is the PVDF sheet. As of the same day, that sheet lists 100 Ohm ± 3 Ohm, a jacket of 0.387 in, conductor DCR of 11 Ohm/1000ft, and 300 V RMS with CMP. 3094A's plenum-number cell is 3095A. The Ohm cells do not match. The RG-6 pair at 75 Ohm and 100 Ohm is on the 3093A and 3132A page.
RG-11, 14 AWG, with a different tape trade name on each sheet
As of November 3, 2026, both sheets are one coax, RG-11, 14 AWG solid bare copper covered steel, conductor diameter 0.064 in. 3094A insulation is foam polyethylene, white, gas injected, nominal insulation diameter 0.280 in (7.11 mm). The shield layers are Duobond II tri-laminate at 100%, aluminum braid at 60%, Duofoil tri-laminate at 100%, and aluminum braid at 40%. The jacket is PVC, nominal diameter 0.407 in (10.3 mm), and the overall diameter is the same 0.407 in (10.3 mm). 3095A insulation is foam FEP, nominal diameter 0.28 in, with no millimeter on that cell. The shield layers are Duofoil at 100%, aluminum braid at 60%, Duofoil at 100%, and aluminum braid at 40%. The jacket is PVDF, nominal diameter 0.387 in, with no millimeter. Applications on both name harsh environment, factory automation, ControlNet, Modbus II, and industrial coax.
| Item | 3094A | 3095A |
|---|---|---|
| Impedance | 75 Ohm | 100 Ohm ± 3 Ohm |
| Jacket | PVC, 0.407 in | PVDF, 0.387 in |
| Conductor DCR | 11.5 Ohm/1000ft | 11 Ohm/1000ft |
| Shield DCR | 1.8 Ohm/1000ft | 3.9 Ohm/1000ft |
| Velocity | 83% | 82% |
| UL temperature | 75°C | 150°C |
| Voltage | 300 V (CMR, CMG) | 300 V RMS |
| Cross-reference | Plenum number 3095A | Non-plenum number 3094A |
75 Ohm on 3094A, 100 Ohm ± 3 Ohm on 3095A
As of November 3, 2026, 3094A lists conductor DCR of 11.5 Ohm/1000ft with no Ohm/km on that cell, outer-shield DCR of 1.8 Ohm/1000ft (5.9 Ohm/km), capacitance of 16.3 pF/ft (53.5 pF/m), impedance of 75 Ohm, and velocity of 83%. It does not print a delay or an inductance in that electrical block. 3095A lists conductor DCR of 11 Ohm/1000ft, and both the outer-shield DCR cell and the outer-conductor DCR cell print 3.9 Ohm/1000ft. Capacitance is 16.5 pF/ft with no pF/m. Inductance is 0.097 µH/ft. Impedance is 100 Ohm ± 3 Ohm. Delay is 1.2 ns/ft. Velocity is 82%. Attenuation in dB/100ft is 0.16 and 0.17 at 1 MHz, 0.38 and 0.4 at 10 MHz, 0.83 and 1.2 at 50 MHz, 1.17 and 1.7 at 100 MHz, 1.60 and 2.5 at 200 MHz, and 2.30 and 3.5 at 400 MHz, 3094A first in each pair. 3095A's structural-return-loss table prints 20 dB at 1 MHz. The later frequency cells in that table are blank. A separate note says SLR minimum 20 dB from 5 MHz to 50 MHz.
CMR on 3094A, CMP on 3095A, and a suitability line that still says plenum
As of November 3, 2026, 3094A lists UL temperature 75°C and operating temperature -30°C to 75°C. Installation bend minimum is 4 in (100 mm). The sheet does not print a stationary bend. Pull tension is 234 lbs (106 kg). Bulk weight is 60 lbs/1000ft. The suitability cell includes indoor plenum, indoor, outdoor, sunlight resistance, and aerial when supported by messenger wire. Flammability is UL 1666 riser. NEC / UL compliance is CMR, CL2R. The voltage cell is 300 V (CMR, CMG). CEC compliance is CMG. The plenum-number cell names 3095A. Notes say tap marks every 2.6 meters. 3095A lists UL temperature 150°C and operating temperature -20°C to +150°C. Minimum minor-axis bend radius is 4 in. Maximum recommended pulling tension is 309 lbs, with no kilogram. Bulk weight is 68 lbs/1000ft. Plenum (Y/N) is Yes. NEC articles is Article 800. NEC/(UL) compliance is CMP. CEC compliance is CMP. Voltage is 300 V RMS, printed again in the flammability block. Suitability burial is Yes. Suitability outdoor is Yes. Flammability is NFPA 262 and CSA FT6. Notes say sweep tested 5 MHz to 400 MHz, and tap marks every 2.6 meters. Page revision is 0.516, dated 02-20-2026, on 3094A, and 0.309, dated 10-27-2026, on 3095A.
Gray DEC reels on 3094A
As of November 3, 2026, 3094A variant rows are gray, DEC: 3094A F2V500 at 500 ft, 3094A F2V1000 at 1,000 ft, and 3094A F2V2000 at 2,000 ft with footnote C. The 3095A sheet does not print a put-up table. The RG-6 plenum number on 3092A remains 3093A, which is a different diameter and a different part, on the 3093A and 3132A page.
What to copy onto the cable line
- Part: 3094A or 3095A, from the sheet opened November 3, 2026.
- Coax: RG-11, 14 AWG solid bare copper covered steel, 0.064 in.
- Impedance: 75 Ohm, or 100 Ohm ± 3 Ohm.
- Jacket: PVC at 0.407 in, or PVDF at 0.387 in.
- Conductor DCR: 11.5 Ohm/1000ft, or 11 Ohm/1000ft.
- Shield DCR: 1.8 Ohm/1000ft, or 3.9 Ohm/1000ft.
- Temperature: UL 75°C and operating -30°C to 75°C, or UL 150°C and operating -20°C to +150°C.
- Listing: 300 V (CMR, CMG) with NEC CMR, CL2R, or 300 V RMS with CMP.
Questions these sheets answer
Does the plenum-number cell keep 75 Ohm?
3094A prints 75 Ohm, as of November 3, 2026. 3095A prints 100 Ohm ± 3 Ohm. The sheets name each other. The impedance cell is copied from the sheet for the part being ordered.
Does 3094A's suitability line make it CMP?
3094A's suitability cell includes the words indoor plenum, as of November 3, 2026. The voltage cell is 300 V (CMR, CMG). NEC compliance is CMR, CL2R. The plenum-number cell names 3095A, and 3095A's compliance cell is CMP.
Which shield cell is 3.9 Ohm/1000ft?
3095A prints 3.9 Ohm/1000ft in the outer-shield DCR cell and again in the outer-conductor DCR cell, as of November 3, 2026. 3094A's outer-shield DCR is 1.8 Ohm/1000ft (5.9 Ohm/km).
Sources
Impedance, jacket, DCR, temperature, and the cross-reference numbers are from the Belden 3094A and 3095A technical data sheets. Both were opened November 3, 2026. Later structural-return-loss frequency cells on 3095A are blank. The RG-6 comparison is a different pair of part numbers.