Skip to the guide

Industrial networking

Belden 3093A at 75 Ohm or 3132A at 100 Ohm

Use 3093A when the plenum-number cell on 3092A is the pointer. Use 3132A when the category high-temp link is the pointer.

Rust Belt Industrials · October 25, 2026 · Updated October 28, 2026 · 6 min read

On this page

Use Belden 3093A when the pointer is the plenum-number cell on 3092A. As of October 25, 2026, 3093A lists 75 Ohm, a PVDF jacket with a nominal diameter of 0.274 in (6.96 mm), and an operating range of -20°C to +150°C. Use Belden 3132A when the pointer is the high-temp/plenum link under Modbus II on Belden's category page. As of the same day, 3132A lists 100 Ohm ± 3 Ohm, a PVDF jacket with a nominal diameter of 0.274 in, and the same operating range of -20°C to +150°C. The 22 AWG plenum pair is a different cable, on the 8777 and 88777 page.

Two documents point at two part numbers

The 3092A page opened October 25, 2026 prints 3093A in the plenum-number cell. It does not print 3132A there. The Modbus category page, opened the same day, puts 3132A on the high-temp/plenum line under the Modbus II row. That row's standard product link remains 3092A, 18 AWG, 1 coax, standard quad shield. A request names the document that pointed at the part, then copies the impedance from the product page that document opened.

Both product pages name ControlNet and Modbus II in the suitable-applications cell, as of October 25, 2026. 3093A's title adds CMP and high temp 150C. 3132A's title adds CMP and does not add the words high temp. The non-plenum number on 3093A is 3092A. The non-plenum number on 3132A is 3131A. 3131A, opened October 28, 2026, lists 120 Ohm and a PVC jacket. That pair is on the 3131A and 3132A page. The standard 75 Ohm coax, including pull tension and the PVC jacket, is on the 8777 and 3092A page.

Same gauge, different first tape

As of October 25, 2026, both pages list one 18 AWG solid bare-copper-covered-steel conductor. 3093A's conductor nominal diameter is 0.040 in. 3132A's conductor nominal diameter is 0.04 in. Insulation on both pages is foam FEP, white on 3093A. 3093A's nominal insulation diameter is 0.170 in (4.32 mm). 3132A's nominal insulation diameter is 0.17 in, with no millimeter in that cell.

The shield is four layers on both pages. On 3093A the first tape is Duobond II at 100%, then an aluminum braid at 60%, a Duofoil tape at 100%, and an aluminum braid at 40%. On 3132A the first tape is Duofoil at 100%, then an aluminum braid at 60%, a Duofoil tape at 100%, and an aluminum braid at 40%. The jacket on both pages is PVDF. 3093A prints 0.274 in (6.96 mm) for the jacket and for the overall diameter. 3132A prints 0.274 in for the jacket and does not add a millimeter in that cell. 3132A's part-number row opened October 25, 2026 is 3132A F2V1000, gray DEC, reel, 1,000 ft.

High-temp Modbus II rows from the pages opened October 25, 2026.
Item3093A3132A
What pointed herePlenum-number cell on 3092ACategory high-temp link under Modbus II
Impedance75 Ohm100 Ohm ± 3 Ohm
First shield tapeDuobond II, 100%Duofoil, 100%
Outer-shield DCR2.6 Ohm/1000ft (8.5 Ohm/km)7.2 Ohm/1000ft
JacketPVDF, 0.274 in (6.96 mm)PVDF, 0.274 in
Operating range-20°C to +150°C-20°C to +150°C
Non-plenum number3092A3131A

75 Ohm and 100 Ohm are different cells

As of October 25, 2026, 3093A lists conductor DCR of 28 Ohm/1000ft, outer-shield DCR of 2.6 Ohm/1000ft (8.5 Ohm/km), capacitance of 16.5 pF/ft (54.1 pF/m) conductor to shield, impedance of 75 Ohm, and velocity of 82%. Minimum structural return loss is 23 dB from 5 MHz to 50 MHz. Nominal attenuation is 0.34 dB/100ft at 1 MHz, 0.58 dB/100ft at 10 MHz, and 1.99 dB/100ft at 100 MHz. The table also prints 2, 5, 20, 50, 200, 300, and 400 MHz. UL voltage is 300 V (CMP).

As of October 25, 2026, 3132A lists nominal conductor DCR of 28 Ohm/1000ft, nominal outer-shield DCR of 7.2 Ohm/1000ft, and an outer-conductor DCR column that also reads 7.2 Ohm/1000ft. Capacitance is 16.3 pF/ft. Inductance is 0.093 µH/ft. Delay is 1.2 ns/ft. Velocity is 82%. Impedance is 100 Ohm with a tolerance of ± 3 Ohm. The voltage cell and a later UL voltage-rating line both read 300 V RMS. Nominal insertion loss is 0.36 dB/100ft at 1 MHz, 0.65 dB/100ft at 10 MHz, and 2.12 dB/100ft at 100 MHz, with further rows through 400 MHz. The structural-return-loss table prints 23 dB at 1 MHz. The cells from 2 MHz through 400 MHz are empty. Notes print tilt of .48 dB/100 M from 5 to 10 MHz and .93 dB/100 M from 10 to 20 MHz, and they say the cable is sweep tested from 5 to 400 MHz. 3093A's electrical table does not print inductance, delay, or those tilt lines.

150°C on both, with different listing details

As of October 25, 2026, 3093A lists UL temperature 150°C and operating temperature -20°C to +150°C. Installation bend minimum is 2.75 in (69.9 mm). Maximum pull tension is 104 lbs (47.2 kg). Weight is 36 lbs/1000ft. Environmental suitability is indoor plenum, indoor, outdoor, aerial when supported by messenger wire, and burial. Flammability is NFPA 262. NEC and CEC compliance are CMP. Notes say blue is available as standard in the 1,000 ft put-up only, and that the cable is suitable for outdoor and direct burial. Page revision is 0.503, dated 02-20-2026.

As of October 25, 2026, 3132A lists UL temperature 150°C and operating temperature -20°C to +150°C. Minimum minor-axis bend radius is 2.75 in, with no millimeter in that cell. Maximum recommended pulling tension is 104 lbs, with no kilogram in that cell. Weight is 43 lbs/1000ft. Suitability cells say burial yes and outdoor yes. Flammability is NFPA 262 and FT6. NEC and CEC compliance are CMP. Plenum is marked yes. Notes say tap marks every 2.6 meters. Page revision is 0.418, dated 02-20-2026. A high-flex PVC coax at 75 Ohm is a different part, on the 3092F page.

What to copy onto the cable line

  • Pointer: the 3092A plenum-number cell, or the category high-temp link, from pages opened October 25, 2026.
  • Part: 3093A or 3132A.
  • Impedance: 75 Ohm, or 100 Ohm ± 3 Ohm.
  • Jacket: PVDF, and the diameter cell on that page, 0.274 in (6.96 mm) or 0.274 in.
  • Operating range: -20°C to +150°C, UL temperature 150°C.
  • Shield DCR from that page: 2.6 Ohm/1000ft, or 7.2 Ohm/1000ft.

3093A or 3132A note

Name which document pointed at the part, and copy that part's impedance.

This prepares a request. It does not send one.

Questions these pages answer

Is 3132A the plenum number printed on 3092A?

The plenum-number cell on 3092A is 3093A, as of October 25, 2026. 3132A is the product link on the category high-temp line under Modbus II. The two pointers are different, and the impedance cells are 75 Ohm and 100 Ohm.

Does 0.274 in mean the impedance matches?

Both jacket cells print 0.274 in, as of October 25, 2026. 3093A also prints 6.96 mm. The impedance cells remain 75 Ohm and 100 Ohm ± 3 Ohm. Diameter does not choose the impedance.

Where does 23 dB apply?

On 3093A, 23 dB is the minimum structural return loss from 5 MHz to 50 MHz. On 3132A, 23 dB is filled in at 1 MHz, and the later frequency cells on that table are empty. Copy the span the page fills in.

Sources

Impedance, shield, jacket, temperature, and the non-plenum numbers are from the Belden 3093A and 3132A pages. The plenum-number cell is from the Belden 3092A page. The high-temp link under Modbus II is from the Belden Modbus category page. All four were opened October 25, 2026. The 3131A sheet was opened October 28, 2026.