Industrial networking
Belden 82841 PVC or 89841 FEP for One-Pair CMP
Use 82841 for the PVC CMP jacket at UL 75°C and 0°C to +75°C. Use 89841 for the FEP CMP jacket at UL 200°C and -70°C to +200°C. Both list 0.204 in, 120 Ohm, and 4 A.
On this page
Use Belden 82841 when the one-pair CMP cable is the PVC jacket. As of November 5, 2026, that sheet lists a PVC jacket of 0.204 in (5.18 mm), UL temperature 75°C, and an operating range of 0°C to +75°C. Use Belden 89841 when the one-pair CMP cable is the FEP jacket. As of the same day, that sheet lists an FEP jacket of 0.204 in (5.18 mm), UL temperature 200°C, and an operating range of -70°C to +200°C. Both list one 24 AWG pair, 120 Ohm, 4 A per conductor at 25°C, and 300 V (CMP). 9841's plenum-number cell, opened the same day, names 82841 and 89841. The non-plenum CM cable at 0.232 in is on the 9841 and 82841 page.
FEP foam insulation on both, and the jacket material is the split
As of November 5, 2026, both sheets list one pair of 24 AWG 7x32 tinned copper. Insulation is FEP foam, 0.025 in (0.64 mm) thick, nominal insulation diameter 0.074 in (1.9 mm). Pair colors are white/blue stripe and blue/white stripe. The shield is a 100% bi-laminate tape with a 24 AWG (7x32) tinned-copper drain, plus a 90% tinned-copper braid. Jacket thickness is 0.015 in (0.38 mm) on both. 82841's jacket cell is PVC. 89841's jacket cell is FEP. Nominal jacket diameter is 0.204 in (5.18 mm) on both, and neither sheet prints a jacket OD tolerance. Suitable applications on both name RS-485, POS, computer communications, low voltage analog and digital signals, line level audio, panel wiring, and serial communication for PLCs, VFDs, HMIs, motors, RTU, and SCADA. Neither plenum sheet prints the other part number. The grouping is the plenum-number cell on 9841.
| Item | 82841 | 89841 |
|---|---|---|
| Jacket | PVC, 0.204 in | FEP, 0.204 in |
| Insulation | FEP foam, 0.074 in | FEP foam, 0.074 in |
| Impedance | 120 Ohm | 120 Ohm |
| Current | 4 A at 25°C | 4 A at 25°C |
| UL temperature | 75°C | 200°C |
| Operating range | 0°C to +75°C | -70°C to +200°C |
| Suitability | Indoor | Indoor, oil resistance |
| Put-up color | Natural | Red |
120 Ohm, 24 Ohm/1000ft, and 4 A match
As of November 5, 2026, both sheets list conductor DCR of 24 Ohm/1000ft, with no kilometer figure in that cell. Capacitance conductor to conductor is 12 pF/ft (39 pF/m). Capacitance to the other conductors plus shield is 22 pF/ft (72 pF/m). Impedance is 120 Ohm. Velocity is 76%. Neither electrical block prints a delay. Outer-shield DCR is 3.1 Ohm/1000ft (10 Ohm/km). Current is 4 A per conductor at 25°C. Nominal insertion loss at 1 MHz is 0.6 dB/100ft. The high-frequency table does not print a row past 1 MHz. Voltage is 300 V (CMP). NEC / UL compliance is Article 800, CMP. CEC / C(UL) compliance is CMP. Neither sheet prints an AWM line.
Oil resistance and -70°C are on 89841
As of November 5, 2026, 82841's suitability cell is indoor. UL temperature is 75°C. Operating temperature is 0°C to +75°C. The sheet does not print installation or storage columns. Bend radius is 2.25 in (57.2 mm) for stationary and installation use. Pull tension is 45.7 lbs (20.7 kg). Bulk weight is 26 lbs/1000ft. Flammability is NFPA 262, UL 910 (Plenum), FT6, and IEC 60332-1-2. CPR is Euroclass Eca. The compliance block does not print REACH. 89841's suitability cell is indoor and oil resistance. The notes cell says oil and gas resistant. UL temperature is 200°C. Operating temperature is -70°C to +200°C. Bend radius, pull tension, flammability, CMP, and the 1 MHz loss match 82841. Bulk weight is 27 lbs/1000ft. The European-directive cell includes REACH. Page revision is 0.549, dated 02-20-2026, on 82841, and 0.578, dated 02-20-2026, on 89841. Both non-plenum-number cells print 9841, 9841ZH.
Natural on 82841, red on 89841
As of November 5, 2026, 82841's variant rows are natural: 82841 8771000, 82841 877500, and 82841 8775000. Footnote C, crate reel put-up, is on 8771000. The table does not print a length. 89841's variant rows are red: 89841 0021000, 89841 002500, and 89841 0025000. Footnote C is on 0021000. That table does not print a length either. The jacket compound comes from the material cell. The put-up color comes from the row being ordered. 9841's own put-ups, chrome and other colors at 0.232 in, stay on the non-plenum sheet.
What to copy onto the cable line
- Part: 82841 or 89841, from the sheet opened November 5, 2026.
- Pair: 1 of 24 AWG 7x32, FEP foam, white/blue stripe and blue/white stripe.
- Jacket: PVC at 0.204 in, or FEP at 0.204 in.
- Impedance: 120 Ohm. Current: 4 A at 25°C. Conductor DCR: 24 Ohm/1000ft.
- Temperature: UL 75°C and 0°C to +75°C, or UL 200°C and -70°C to +200°C.
- Listing: 300 V (CMP), Article 800, CMP.
- Suitability: indoor, or indoor and oil resistance. 89841's notes also say oil and gas resistant.
- Cross-reference: 9841's plenum-number cell names both. Each plenum sheet's non-plenum cell names 9841, 9841ZH.
Questions these sheets answer
Does the FEP jacket change 0.204 in?
Both jacket cells print 0.204 in (5.18 mm), as of November 5, 2026. Current, impedance, conductor DCR, and shield DCR also match. Temperature, suitability, weight, and put-up color do not.
Does 89841 keep 0°C?
82841's operating range is 0°C to +75°C, as of November 5, 2026. 89841's operating range is -70°C to +200°C. The FEP sheet does not print 0°C as the low.
Which oil line is on 89841?
89841's suitability cell says indoor and oil resistance, as of November 5, 2026. The notes cell says oil and gas resistant. 82841's suitability cell says indoor and does not print an oil line.
Sources
Jacket, temperature, impedance, current, and the non-plenum cells are from the Belden 82841 and 89841 technical data sheets. The plenum-number cell that names both parts is from the Belden 9841 technical data sheet. All three were opened November 5, 2026.