Skip to the guide

Industrial networking

Belden 87777 PVDF or 82777 LS-PVC Plenum

Use 87777 for the PVDF jacket at 50 Ohm and -20°C to +150°C. Use 82777 for the LS-PVC title at 46 Ohm and 0°C to +90°C.

Rust Belt Industrials · October 27, 2026 · 6 min read

On this page

Use Belden 87777 when the 22 AWG 3-pair plenum cable is the PVDF jacket at 50 Ohm, with an operating range of -20°C to +150°C and an applications line that includes outdoor and burial. As of October 27, 2026, that sheet lists a nominal jacket diameter of 0.234 in, CMP, and 3.5 A per conductor at 25°C. Use Belden 82777 when the cable is the LS-PVC title at 46 Ohm, with an operating range of 0°C to +90°C and an applications line that says indoor plenum. As of the same day, that sheet lists a nominal jacket diameter of 0.237 in (6.02 mm), CMP, and 1.96 A per conductor at 25°C. Both sheets name 8777 as the non-plenum number. The 8777 sheet opened the same day lists plenum numbers 88777, 87777, and 82777. The FEP plenum comparison is 88777, on the 8777 and 88777 page.

8777 names both plenum numbers

The 8777 technical data sheet opened October 27, 2026 prints a plenum-number cell of 88777, 87777, and 82777. 87777's jacket material cell is PVDF, polyvinylidene fluoride, nominal diameter 0.234 in, nominal wall 0.014 in. That sheet does not print millimeters on those two cells. 82777's title says LS-PVC. Its jacket material cell says PVC, polyvinyl chloride, nominal thickness 0.017 in (0.43 mm), nominal diameter 0.237 in (6.02 mm). The request names the jacket and the impedance with the part: PVDF and 50 Ohm, or the LS-PVC title and 46 Ohm.

FEP pairs, with different drain stranding

As of October 27, 2026, both sheets list three pairs of 22 AWG, 7x30, tinned copper. Colors on both are black and red, black and white, and black and green. 87777 insulation is FEP, nominal wall 0.01 in, and the conductor nominal diameter is 0.03 in. The insulation table does not print an insulation diameter or a millimeter wall. 82777 insulation is FEP, 0.011 in (0.28 mm), nominal insulation diameter 0.050 in (1.3 mm). Each pair on both sheets has a bi-laminate tape at 100% coverage. The 87777 drain is 22 AWG stranded tinned copper. The construction cell says Stranded and does not print 7x30 or 19x34 for that drain. The 82777 drain is 22 AWG (19x34) tinned copper. 87777's outer-shield cell prints No Shield. 82777 does not print an outer-shield block.

87777 and 82777 rows from the sheets opened October 27, 2026.
Item8777782777
Jacket cellPVDF, 0.234 inPVC, 0.237 in (6.02 mm)
Title jacket wordsPVDF Jkt, CMPLS-PVC Jkt, CMP
Impedance50 Ohm46 Ohm
Current at 25°C3.5 A per conductor1.96 A per conductor
Operating range-20°C to +150°C0°C to +90°C
Applications lineOutdoor and burial, among othersIndoor plenum
Non-plenum number87778777
Velocity69%62%

50 Ohm on 87777, 46 Ohm on 82777

As of October 27, 2026, 87777 lists nominal characteristic impedance of 50 Ohm, inductance of 0.18 µH/ft, velocity of 69%, nominal delay of 1.47 ns/ft, and maximum delay skew of 69 ns/100m. Capacitance is 31 pF/ft conductor to conductor and 67 pF/ft conductor to other, with no metric figure in those cells. Maximum conductor DCR is 160 Ohm/km. Individual pair nominal shield DCR is 11.3 Ohm/1000ft. The sheet does not print a nominal conductor DCR in Ohm/1000ft. Current is 3.5 A per conductor at 25°C. Voltage is 300 V RMS. NEC/(UL) compliance is CMP. The cell does not print Article 800.

As of October 27, 2026, 82777 lists nominal characteristic impedance of 46 Ohm, nominal conductor DCR of 18.2 Ohm/1000ft, maximum conductor DCR of 160 Ohm/km (49 Ohm/1000ft), and nominal inner-shield DCR of 10.46 Ohm/1000ft (34.32 Ohm/km). Capacitance is 35 pF/ft (110 pF/m) conductor to conductor and 76 pF/ft (250 pF/m) conductor to other. Inductance is 0.18 µH/ft (0.59 µH/m). Velocity is 62%. The sheet does not print a delay cell. Current is 1.96 A per conductor at 25°C. Voltage is 300 V. NEC compliance is Article 800, CMP. CEC compliance is CMP on both sheets.

Outdoor and burial on 87777, indoor plenum on 82777

87777's applications cell, as of October 27, 2026, lists extreme high temperature environments, chemical resistant, outdoor and burial, and the low-voltage analog, digital-control, audio, voice, and panel-wiring uses. Plenum (Y/N) is Yes. Operating temperature is -20°C to +150°C. The sheet does not print a separate UL temperature cell. Flammability is NFPA 262 Plenum Flame Test (UL910) and CSA FT6. The sheet does not print an IEC flammability line or a CPR class. Bulk weight is 36 lbs/1000ft. Maximum recommended pulling tension is 82 lbs, with no kilogram in that cell. Minimum minor-axis bend radius is 2.5 in, with no millimeter in that cell. Page revision is 0.348, dated 02-03-2025. Put-ups are 87777 0021000 and 87777 002500, both red. Those rows do not print a length.

82777's applications cell, as of October 27, 2026, lists indoor plenum applications and the same low-voltage family. It does not list outdoor or burial. UL temperature is 90°C. Operating temperature is 0°C to +90°C. Flammability is NFPA 262 (UL910), FT6, and IEC 60332-1-2. CPR is Euroclass Eca. UK regulation is UKCA Mark. Bulk weight is 36 lbs/1000ft, the same pound figure as 87777, with no kilogram. Maximum pull tension is 64.1 lbs (29.1 kg). Minimum bend radius is 2.37 in (60.2 mm), stationary and installation. Page revision is 0.461, dated 09-07-2025. Put-ups are natural: 82777 8771000 with footnote C, crate reel put-up, plus 82777 877U1000 and 82777 877U500. Those rows do not print a length.

What to copy onto the cable line

  • Part: 87777 or 82777, from the sheet opened October 27, 2026.
  • Non-plenum number: 8777, on both sheets, and on the 8777 plenum-number cell.
  • Jacket: PVDF at 0.234 in, or PVC at 0.237 in (6.02 mm), and record the LS-PVC title on 82777.
  • Impedance: 50 Ohm, or 46 Ohm.
  • Current: 3.5 A per conductor at 25°C, or 1.96 A per conductor at 25°C.
  • Place: outdoor and burial on the 87777 applications line, or indoor plenum on the 82777 applications line.

87777 or 82777 note

Name the plenum jacket and copy the impedance from that sheet.

This prepares a request. It does not send one.

Questions these sheets answer

Does CMP mean both stay at 50 Ohm?

87777 prints 50 Ohm, as of October 27, 2026. 82777 prints 46 Ohm. Both print CMP and name 8777 as the non-plenum number. Copy the Ohm cell with the part number.

Which drain construction goes on the request?

87777's drain cell says 22 AWG stranded, as of October 27, 2026. 82777's drain cell says 22 AWG (19x34). Copy the construction the sheet prints. The 7x30 figure stays on the conductor row.

Which current belongs on a 25°C line?

Both current cells are at 25°C, as of October 27, 2026. 87777 is 3.5 A per conductor. 82777 is 1.96 A per conductor.

Sources

Jacket, impedance, current, temperature, and the applications line are from the Belden 87777 and 82777 technical data sheets. The plenum-number cell that names both is from the Belden 8777 technical data sheet. All three were opened October 27, 2026. 88777 was not used for a new cell on this page.