Liquid cooling
Staubli CGD at 16 bar or SPT/CG at 40 bar
Use CGD for misalignment up to 1 mm at 16 bar. Use SPT/CG for ball locking at 40 bar.
On this page
Use Staubli CGD when the coupling has to accept misalignment up to 1 mm. As of October 24, 2026, the CGD page lists nominal diameter DN 03 to 12 mm and maximum allowable pressure of 16 bar (232 PSI). Use Staubli SPT/CG when the coupling is the ball-locking series. As of the same day, the SPT/CG page lists DN 05 to 25 mm and maximum allowable pressure of 40 bar (580 PSI). Both pressure lines carry an asterisk: depending on the model and operating conditions. UQD size codes are a different series, on the UQD size page.
CGD is the 1 mm blind-mate series, and SPT/CG is the ball-locking series
The CGD page opened October 24, 2026 titles the series clean-break blind-mate connectors. It says the couplings are non-spill and non-drip, and that rackable systems can compensate for misalignment up to 1 mm between axes. The applications list on that page names electronics, converters, medical imaging, telecommunications, broadcasting, supercomputers, and data centers. Nominal diameter is DN 03 to 12 mm. Maximum allowable pressure is 16 bar (232 PSI), with the asterisk for model and operating conditions. The related card for SPT/CG on that same page repeats DN 05 to 25 mm and 40 bar.
The SPT/CG page opened October 24, 2026 titles the series an aluminum clean-break coupling and describes ball locking. It says the connectors are corrosion-resistant, small, and light, and that the non-spill flush face avoids a drip at disconnection. The applications list names cooling of electronics, including HPC, converters, data centers, radar, and medical imaging equipment, plus a water cooling unit and thermoregulation. Nominal diameter is DN 05 to 25 mm. Maximum allowable pressure is 40 bar (580 PSI), with the same asterisk. The related card for CGD on that page repeats DN 03 to 12 mm and 16 bar.
| Item | CGD | SPT/CG |
|---|---|---|
| Lock | Blind mate, misalignment up to 1 mm | Ball locking, flush face |
| Nominal diameter | DN 03 to 12 mm | DN 05 to 25 mm |
| Maximum allowable pressure | 16 bar (232 PSI) | 40 bar (580 PSI) |
| Pressure note | Depends on the model and operating conditions | Depends on the model and operating conditions |
| Body | Nickel-plated brass on some sizes and styles, or CGD/L aluminum | Aluminum alloy with a treated surface |
| PAO on the fluid list | Listed | Left off the SPT/CG list |
The fluid lists match on five names and differ on PAO
As of October 24, 2026, the CGD fluid list is glycol water, heat transfer oils, esters, cooling water, kerosene, and PAO. The SPT/CG fluid list is glycol water, heat transfer oil, esters, cooling water, and kerosene. A loop that names PAO uses the CGD list, which is the list that names PAO. Glycol water is on both lists. Concentration, freeze point, and fluid temperature stay off the request until a page prints them for the series.
Body metal and the seal line are different cells
As of October 24, 2026, CGD construction is nickel-plated brass for some sizes and styles, and CGD/L is aluminum alloy with a surface treatment. SPT/CG construction is aluminum alloy with a treated surface, available with 4 types of seals. The SPT/CG page does not name the four compounds in that cell, so the request leaves the compound blank until a page that names it is attached. An optional release valve on the SPT/CG page is described as keeping pressure from rising if the circuit is exposed to a heat source during storage. The sentence does not add a storage temperature.
Temperature, Cv, and flow are not printed on the CGD or SPT/CG specification tables opened October 24, 2026. The request leaves those three blank for these series. Pressure and temperature windows for OCP UQD, Danfoss, Gates, and CPC are on the coupling ratings page. Those windows stay with the products named there. Supplier context for blind-mate and hand-mate couplings is on the quick-disconnect page.
What to copy onto the coupling line
- Series: CGD or SPT/CG, from the page opened October 24, 2026.
- Nominal diameter: DN 03 to 12 mm, or DN 05 to 25 mm, and the size inside that range.
- Pressure: 16 bar (232 PSI), or 40 bar (580 PSI), with the model asterisk.
- Misalignment, when the series is CGD: up to 1 mm between axes.
- Fluid, copied from that series list. PAO is on the CGD list.
- Body: nickel-plated brass or CGD/L aluminum, or SPT/CG aluminum. Seal compound only if a page names it.
Questions the two Staubli pages answer
Which series lists 40 bar?
SPT/CG lists 40 bar (580 PSI), as of October 24, 2026. CGD lists 16 bar (232 PSI). Both lines depend on the model and the operating conditions. The related cards on the two pages repeat those same pairs of figures.
Does a DN 16 coupling fall on the CGD page?
CGD stops at DN 12 mm, as of October 24, 2026. SPT/CG runs from DN 05 mm to DN 25 mm, so DN 16 sits on the SPT/CG span. DN 03 sits on the CGD span and outside the SPT/CG span.
Where is the temperature rating?
The specification tables opened October 24, 2026 print diameter, pressure, fluids, and construction. They do not print a temperature, a Cv, or a flow. A temperature on the request has to come from a page that prints one for the size on the drawing.
Sources
Diameter, pressure, the 1 mm misalignment sentence, fluids, and body materials for CGD are from the CGD page. Diameter, pressure, ball locking, the fluid list, the four-seal line, and the release-valve sentence for SPT/CG are from the SPT/CG page. Both were opened October 24, 2026. Temperature, Cv, and flow were not on those specification tables.